标准自动视野计与GDx VCC测量值之间的关系。

The relationship between standard automated perimetry and GDx VCC measurements.

作者信息

Reus Nicolaas J, Lemij Hans G

机构信息

Glaucoma Service, The Rotterdam Eye Hospital, Rotterdam, The Netherlands.

出版信息

Invest Ophthalmol Vis Sci. 2004 Mar;45(3):840-5. doi: 10.1167/iovs.03-0646.

Abstract

PURPOSE

To investigate the relationship between retinal light sensitivity measured with standard automated perimetry (SAP) and retardation of the peripapillary retinal nerve fiber layer (RNFL) measured with the GDx VCC (Laser Diagnostic Technologies, Inc., San Diego, CA).

METHODS

Forty-seven healthy subjects and 101 patients with glaucoma were examined with SAP and with the commercially available scanning laser polarimeter GDx VCC, with automated individualized compensation of anterior segment birefringence. Individual visual field test points and peripapillary RNFL retardation measurements were grouped into six corresponding sectors. The correlation between perimetry and GDx VCC measurements was determined, and the relationship between RNFL retardation and perimetry, expressed both in the standard decibel scale and in an unlogged scale, was described with linear regression analysis.

RESULTS

A statistically significant correlation was found in most sectors between perimetry and GDx VCC measurements in patients with glaucoma, but not in healthy subjects. A linear relationship was found between the unlogged sensitivities and GDx VCC measurements for the superotemporal and inferotemporal sectors. In the decibel scale, this relationship was curvilinear.

CONCLUSIONS

GDx VCC measurements of the peripapillary RNFL relate well with functional loss in glaucoma. Based on the observed relationships between function and structure, patients with mild to moderate visual field loss in glaucoma may be better monitored with the GDx VCC and patients who have severe loss, with SAP.

摘要

目的

研究使用标准自动视野计(SAP)测量的视网膜光敏感度与使用GDx VCC(激光诊断技术公司,加利福尼亚州圣地亚哥)测量的视乳头周围视网膜神经纤维层(RNFL)厚度之间的关系。

方法

对47名健康受试者和101名青光眼患者进行了SAP检查以及使用市售的扫描激光偏振仪GDx VCC检查,并对眼前节双折射进行自动个体化补偿。将个体视野测试点和视乳头周围RNFL厚度测量值分为六个相应的扇区。确定视野计与GDx VCC测量值之间的相关性,并通过线性回归分析描述RNFL厚度与视野计测量值之间的关系,分别以标准分贝尺度和未记录尺度表示。

结果

在青光眼患者的大多数扇区中,视野计与GDx VCC测量值之间存在统计学上的显著相关性,但在健康受试者中未发现。在颞上和颞下扇区,未记录的敏感度与GDx VCC测量值之间发现了线性关系。在分贝尺度上,这种关系是曲线的。

结论

视乳头周围RNFL的GDx VCC测量值与青光眼的功能丧失密切相关。基于观察到的功能与结构之间的关系,青光眼轻度至中度视野丧失的患者可能使用GDx VCC能得到更好的监测,而严重丧失的患者则使用SAP。