Smichowski Patricia, Gómez Dario R, Dawidowski Laura E, Giné María Fernanda, Bellato Ana Claudia Sánchez, Reich Silvia L
Comision Nacional de Energia Atomica, Unidad de Actividad Quimica, Av. Gral. Paz 1499, B1650KNA-San Martin, Argentina.
J Environ Monit. 2004 Apr;6(4):286-94. doi: 10.1039/b312446k. Epub 2004 Feb 20.
A study was undertaken, within the framework of a 3 years national project, to assess the content of 13 elements in airborne particulate matter collected in representative zones of the metropolitan area of Buenos Aires. The sampling strategy followed consisted in collecting simultaneously 67 samples of PM10 particulate matter in 9 sampling sites covering an area of about 30 km2 during one week. The collection was performed on ash-free fibre-glass filters using high volume samplers. A combination of aqua regia and perchloric acid was used for leaching metals from filters. Key elements, namely Al, Ca, Cu, Fe, Mn, Mo, Ni, Pb, S, Sb, Sn, Zn and Zr, were determined by inductively coupled plasma-optical emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) at micro g g(-1) and ng g(-1) levels. Analyte concentration varied from 130 ng g(-1)(Mo) to over 30%(Ca). Multivariate statistical analysis was performed on the data set including the measured elemental compositions for the monitored period. The atmospheric concentration found for Pb confirms the decreasing levels of this element since the introduction of unleaded gasoline in 1995: 88 ng m(-3)(2001) < 220 ng m(-3)(1997) < 3900 ng m(-3)(1994). The average S concentration above 3 microg m(-3) is somehow unexpectedly high for Buenos Aires since the relatively low S content of liquid fuels and the massive usage of natural gas imply low emissions of this element from combustion activities. To the best of our knowledge, S concentrations are reported for the first time for this city.
在一个为期3年的国家项目框架内,开展了一项研究,以评估在布宜诺斯艾利斯大都市区代表性区域采集的空气颗粒物中13种元素的含量。采用的采样策略是,在一周内,使用大容量采样器,在覆盖面积约30平方公里的9个采样点同时采集67个PM10颗粒物样本。采集工作在无灰玻璃纤维滤膜上进行。采用王水和高氯酸的组合从滤膜中浸出金属。通过电感耦合等离子体发射光谱法(ICP-OES)和电感耦合等离子体质谱法(ICP-MS)测定了关键元素,即铝、钙、铜、铁、锰、钼、镍、铅、硫、锑、锡、锌和锆,检测限分别为微克/克(-1)和纳克/克(-1)。分析物浓度从130纳克/克(钼)到超过30%(钙)不等。对数据集进行了多元统计分析,数据集包括监测期内测得的元素组成。铅的大气浓度证实了自1995年引入无铅汽油以来该元素含量的下降:88纳克/立方米(2001年)<220纳克/立方米(1997年)<3900纳克/立方米(1994年)。布宜诺斯艾利斯的平均硫浓度高于3微克/立方米,这在某种程度上出乎意料地高,因为液体燃料的硫含量相对较低,且天然气的大量使用意味着燃烧活动中该元素的排放量较低。据我们所知,首次报道了该城市的硫浓度。