This paper describes workplace dermal exposure measurements that were carried out by the Health and Safety Laboratory as part of the EU RISKOFDERM project to measure dust contamination. Exposure to dry powder spray paints was measured at five sites on 12 subjects. Twenty-two samples were obtained, of which eight contained triglycidyl isocyanurate (TGIC) and 14 did not. All subjects wore Tyvek whole body oversuits and some wore sampling gloves. These were either analysed in their entirety to extract the TGIC or surface scanned over representative areas using a portable X-ray fluorescence spectrometer (PXRF) to detect barium or titanium in the fillers of the paints. The method of Dirichlet tessellation was used to map the scans and the technique was developed further for these studies to extend measurements to gloves and to take limits of detection into consideration. The PXRF allowed dusts to be measured in situ that would otherwise be difficult to extract from the material and analyse by other means. The geometric mean surface loading rate of the 22 oversuits was 43 micro g/cm/(2)/h (GSD = 6.0) and of the 23 pairs of sampling gloves was 970 micro g/cm(2)/h (GSD = 8.6). Exposure patterns could be attributed to the arrangements of the subjects, spray booths and the workpieces. Similar exposures were found for TGIC and titanium fillers in factories with similar methods of ventilation.

摘要

本文描述了健康与安全实验室作为欧盟RISKOFDERM项目的一部分所进行的工作场所皮肤暴露测量,以测量粉尘污染情况。在12名受试者身上的5个场所对干粉喷漆的暴露情况进行了测量。共采集了22个样本,其中8个含有异氰尿酸三缩水甘油酯(TGIC),14个不含。所有受试者均穿着特卫强全身防护服,部分人还戴着采样手套。这些样本要么被全部分析以提取TGIC,要么使用便携式X射线荧光光谱仪(PXRF)在代表性区域进行表面扫描,以检测油漆填料中的钡或钛。采用狄利克雷镶嵌法对扫描结果进行绘图,并且为这些研究进一步改进了该技术,将测量范围扩展到手套,并考虑检测限。PXRF能够对粉尘进行现场测量,否则很难从材料中提取并通过其他方法进行分析。22件防护服的几何平均表面负荷率为43微克/平方厘米/小时(几何标准差=6.0),23副采样手套的几何平均表面负荷率为970微克/平方厘米/小时(几何标准差=8.6)。暴露模式可归因于受试者、喷漆 booths和工件的布置。在通风方法相似的工厂中,TGIC和钛填料的暴露情况相似。 (注:原文中“spray booths”的“booths”可能有误,也许是“spray booths”(喷漆 booths),这里按原文翻译,不太明确其准确含义)

相似文献

6
Dermal exposure to chromium in the grinding of stainless and acid-proof steel.
Ann Occup Hyg. 2004 Apr;48(3):197-202. doi: 10.1093/annhyg/meg073.
10

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验