An automated assay method has been developed for the measurement of serum cholinesterase activity. The samples were prepared by an automated liquid handling unit and incubated for 9.7 min at 30 degrees C, followed by automatic injection into a colorimetric flow injection determination system for acetic acid liberated from acetylcholine by cholinesterase catalytic activity. The coloration reaction employed is based upon the formation of 2-nitrophenylhydrazide utilizing a water-soluble carbodiimide and has a high selectivity for carboxylic acids. The coefficients of variation of the proposed method were 2.4% for within-run analysis (n = 14) and 2.6% for between-run analysis (n = 6). Sera of 55 hospitalized patients were analyzed and the values obtained correlated well with an automated differential pH method (gamma = 0.989).
已开发出一种用于测量血清胆碱酯酶活性的自动化检测方法。样本由自动化液体处理单元制备,并在30℃下孵育9.7分钟,然后自动注入比色流动注射测定系统,以检测胆碱酯酶催化活性从乙酰胆碱释放出的乙酸。所采用的显色反应基于利用水溶性碳二亚胺形成2-硝基苯肼,对羧酸具有高选择性。该方法批内分析(n = 14)的变异系数为2.4%,批间分析(n = 6)的变异系数为2.6%。对55例住院患者的血清进行了分析,所得值与自动差分pH法相关性良好(γ = 0.989)。