Echocardiographic assessment of the Ionescu-Shiley pericardial xenograft in the aortic position.

作者信息

Pechacek Leonard W., Solana Luis, Decastro Carlos M.

机构信息

Clayton Foundation for Research Cardiovascular Laboratories and the Division of Cardiology of St. Luke's Episcopal Hospital and the Texas Heart Institute, Houston, Texas.

出版信息

Cardiovasc Dis. 1981 Jun;8(2):210-215.

Abstract

Echocardiograms of 30 patients with a normally functioning Ionescu-Shiley pericardial xenograft valve in the aortic position were analyzed to delineate the ultrasonic patterns produced by this bioprosthesis. The pericardial leaflets were recorded as thin, discrete echoes that were similar in configuration to the native aortic valve. Maximum systolic excursion of the anterior and posterior leaflets was 19 +/- 0.22 mm (standard deviation.) The presence of multiple echoes produced by the titanium frame was the major technical limitation to echocardiographic imaging of valve motion.

摘要

对30例主动脉位置植入Ionescu-Shiley心包异种移植瓣膜且功能正常的患者进行了超声心动图分析,以描绘这种生物假体产生的超声图像。心包瓣叶记录为薄的、离散的回声,其形态与天然主动脉瓣相似。前后瓣叶的最大收缩期偏移为19±0.22毫米(标准差)。钛框架产生的多个回声的存在是瓣膜运动超声心动图成像的主要技术限制。