Suppr超能文献

对部分牙列缺损患者植入短(≤7毫米)骨内牙种植体的研究结果进行的针对性综述。

A targeted review of study outcomes with short (< or = 7 mm) endosseous dental implants placed in partially edentulous patients.

作者信息

Hagi D, Deporter D A, Pilliar R M, Arenovich T

机构信息

Faculty of Dentistry, University of Toronto, Toronto, ON.

出版信息

J Periodontol. 2004 Jun;75(6):798-804. doi: 10.1902/jop.2004.75.6.798.

Abstract

BACKGROUND

Generally, threaded root-form endosseous dental implants are thought to perform poorly in short lengths (i.e., < 10 mm). However, whether modifications in implant surface geometry will improve performance of short threaded implants is less clear.

METHODS

The relationship between dental implant failure rates and their surface geometry, length, and location (maxilla versus mandible) was explored in the published literature. Using a MEDLINE search (1985 through 2001), studies were sought with the following criteria: 1) data suitable to calculate failure rates of implant lengths < or = 7 mm versus > 7 mm; 2) data separable into maxillary versus mandibular results; 3) criteria for "failure" clearly defined; and 4) minimal functional period of 2 years.

RESULTS

Twelve papers were identified as follows: eight with machined threaded implants, two with acid-treated threaded implants, and two with sintered porous-surfaced press-fit implants. The following results were found: 1) machined surface implants experienced greater failure rates than textured surface implants; 2) with the exception of sintered porous-surfaced implants, 7 mm long dental implants appear to have higher failure rates than those > 7 mm length; and 3) with textured surface implants, higher failure rates were more likely in the maxilla than in the mandible, but with machined surface implants there were no differences in failure rates between maxilla and mandible.

CONCLUSIONS

Dental implant surface geometry is a major determinant in how well these implants perform in short lengths, defined here as lengths of < or = 7 mm. While threaded implants show higher failure rates in short versus longer lengths, sintered porous-surfaced implants perform well in the defined "short" lengths. More studies are needed to better assess the performance of short, acid-washed threaded implants.

摘要

背景

一般认为,螺纹根形牙种植体在短长度(即<10毫米)时表现不佳。然而,种植体表面几何形状的改变是否会改善短螺纹种植体的性能尚不清楚。

方法

在已发表的文献中探讨了牙种植体失败率与其表面几何形状、长度和位置(上颌与下颌)之间的关系。通过MEDLINE搜索(1985年至2001年),寻找符合以下标准的研究:1)适合计算长度≤7毫米与>7毫米的种植体失败率的数据;2)可分为上颌与下颌结果的数据;3)“失败”标准明确界定;4)最短功能期为2年。

结果

确定了12篇论文,如下:8篇关于机械加工螺纹种植体,2篇关于酸处理螺纹种植体,2篇关于烧结多孔表面压配式种植体。发现以下结果:1)机械加工表面种植体的失败率高于纹理表面种植体;2)除烧结多孔表面种植体外,7毫米长的牙种植体似乎比长度>7毫米的种植体有更高的失败率;3)对于纹理表面种植体,上颌的失败率比下颌更可能更高,但对于机械加工表面种植体,上颌和下颌的失败率没有差异。

结论

牙种植体表面几何形状是这些种植体在短长度(此处定义为长度≤7毫米)时性能表现的主要决定因素。虽然螺纹种植体在短长度与长长度时显示出更高的失败率,但烧结多孔表面种植体在定义的“短”长度时表现良好。需要更多研究来更好地评估短的、酸洗螺纹种植体的性能。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验