Alzaga Roberto, Bayona Josep María
IIQAB-CSIC Environmental Chemistry Department, Jordi Girona 18-26, E-08034 Barcelona, Spain.
J Chromatogr A. 2004 Jul 9;1042(1-2):155-62. doi: 10.1016/j.chroma.2004.05.015.
A rapid, selective and simple analytical procedure using tetrabutylammonium as ion pair in conjunction with solid-phase microextraction followed by in-port derivatization-GC-negative ion chemical ionization mass spectrometry was developed. The procedure allows an accurate determination of perfluoroalkylcarboxylic acids in aqueous samples at ng L(-1) levels (i.e. method detection limit 20 ng L(-1) forperfluorodecanoic acid) improving previous GC methods in terms of analysis time and sensitivity. Ammonia as reagent gas in the negative ion chemical ionization mass spectrometry increased the sensitivity at least 3-fold compared to methane for perfluorocarboxylic acid butyl esters. The developed procedure was successfully applied to effluents from wastewater treatment plants (i.e. 0.05-8.2 microg L(-1)) and harbor seawaters.
开发了一种快速、选择性和简单的分析方法,该方法使用四丁基铵作为离子对,结合固相微萃取,然后进行进样口衍生化-气相色谱-负离子化学电离质谱分析。该方法能够准确测定水样中纳克/升水平的全氟烷基羧酸(即全氟癸酸的方法检测限为20纳克/升),在分析时间和灵敏度方面优于以前的气相色谱方法。在负离子化学电离质谱中,使用氨气作为反应气时,全氟羧酸丁酯的灵敏度比使用甲烷时至少提高了3倍。所开发的方法成功应用于污水处理厂的废水(即0.05-8.2微克/升)和港口海水的分析。