Dawson Jennifer Anne, Stainton M Colleen
Nepean Hospital, Sydney, Australia.
Neonatal Netw. 2004 Jul-Aug;23(4):25-32. doi: 10.1891/0730-0832.23.4.25.
To examine the effect of Australian Safe-n-Sound Baby Safety Capsule (BSC) on oxygen saturation (SpO2) values of preterm and term infants ready for discharge home.
A two-group pretest/protest quasi-experimental study compared the effect of the BSC on SpO2.
Thirty-nine low birth weight premature newborn infants and 19 term newborn infants ready for discharge home.
Mean oxygen saturation values and the number of oxygen desaturation events below 90 percent.
The mean SpO2 values for both preterm and term infants were within the normal range (>90-100 percent) for each phase of data collection (baseline, capsule, and recovery). However, mean SpO2 values decreased from baseline during the 60 minutes spent in the BSC for the preterm infants.
研究澳大利亚安全之声婴儿安全舱(BSC)对准备出院回家的早产和足月婴儿血氧饱和度(SpO2)值的影响。
一项两组的前测/后测准实验研究,比较了BSC对SpO2的影响。
39名低出生体重早产新生儿和19名准备出院回家的足月新生儿。
平均血氧饱和度值以及低于90%的血氧饱和度下降事件的数量。
在数据收集的每个阶段(基线、安全舱内、恢复阶段),早产和足月婴儿的平均SpO2值均在正常范围内(>90%-100%)。然而,早产婴儿在安全舱内度过的60分钟内,平均SpO2值较基线有所下降。