• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Reliability of the [13C]-acetate breath test in the measurement of gastric emptying of ethanol solutions: a methodological study.

作者信息

Franke A, Harder H, Singer M V

机构信息

Dept. of Medicine II, University Hospital of Heidelberg at Mannheim, Mannheim, Germany.

出版信息

Scand J Gastroenterol. 2004 Aug;39(8):722-6. doi: 10.1080/00365520410005964.

DOI:10.1080/00365520410005964
PMID:15513355
Abstract

BACKGROUND

The [13C]-acetate breath test is a clinically well-established test for measuring gastric emptying of liquids and correlates significantly with scintigraphy. However, no studies have been undertaken to examine the relationship between gastric emptying measured by the [13C]-acetate breath test and ultrasonography. Furthermore, it is not known how ethanol may affect gastric emptying as measured by the [13C]-acetate breath test. This is particularly important because of the additional steps of absorption, metabolism and exhalation of the tracer involved in the [13C]-acetate breath test compared to the simple measurement of gastric emptying by ultrasonography. The aim of the present study was to examine the relationship between the gastric half emptying times measured by the [13C]-acetate breath test and by ultrasonography and to determine the effect of ethanol on the comparability between both methods.

METHODS

On separate days, 10 healthy, fasted randomly selected subjects received the following solutions by gastric tube: 500 mL water, 4% and 10% (v/v) ethanol, 5.5% and 11.4 % (w/v) glucose. Gastric half emptying times of the test solutions were simultaneously determined using the [13C]-acetate breath test and ultrasonography of the fundus and the antrum.

RESULTS

The gastric emptying rates determined by ultrasonography of the fundus correlated significantly with the results obtained using the [13C]-acetate breath test for all test solutions (r = 0.64-0.92, P < 0.05 for all), whereas ultrasonography of the antrum correlated significantly with the breath test only when water (r = 0.94, P = 0.001) was used. The difference between the mean half-emptying times obtained using the [13C]-acetate breath test and ultrasonography of the fundus was 55 +/- 1.8 min. This difference was significantly longer when 4% and 10% (v/v) ethanol solutions were given (61.2 +/- 3.3 and 71.2 +/- 2.9 min) compared to water (P < 0.05).

CONCLUSIONS

A good correlation was found between gastric emptying as measured by the [13C]-acetate breath test and ultrasonography of the fundus. Measurements that were obtained using the [13C]-acetate breath test demonstrate a longer gastric half emptying time compared with those obtained using ultrasonography. This difference is even more marked when ethanol solutions are used. Presumably, this is because ethanol affects the absorption and/or the hepatic metabolism of the tracer. The [13C]-acetate breath test is therefore not a reliable gastric emptying test for comparison of different solutions, especially when ethanol-containing liquids are used.

摘要

相似文献

1
Reliability of the [13C]-acetate breath test in the measurement of gastric emptying of ethanol solutions: a methodological study.
Scand J Gastroenterol. 2004 Aug;39(8):722-6. doi: 10.1080/00365520410005964.
2
Reproducibility and reliability of the 13C-acetate breath test to measure gastric emptying of liquid meal in infants.用于测量婴儿流食胃排空的13C-醋酸呼气试验的可重复性和可靠性
Nutrition. 2005 Mar;21(3):289-94. doi: 10.1016/j.nut.2004.05.027.
3
Performance of the [13C]-acetate gastric emptying breath test during physical exercise.体育锻炼期间的[13C] - 醋酸盐胃排空呼气试验表现
Eur J Clin Invest. 1999 Nov;29(11):922-8. doi: 10.1046/j.1365-2362.1999.00546.x.
4
Measuring gastric emptying of semisolids in children using the 13C-acetate breath test: a validation study.使用13C-醋酸呼气试验测量儿童半固体食物的胃排空:一项验证研究。
Dig Liver Dis. 2004 Apr;36(4):260-4. doi: 10.1016/j.dld.2003.12.011.
5
[The 13C-acetate breath test for the noninvasive assessment of the gastric emptying of a liquid/solid test meal in diabetics].[13C-乙酸呼气试验用于糖尿病患者液体/固体试验餐胃排空的无创评估]
Dtsch Med Wochenschr. 1996 May 31;121(22):713-8. doi: 10.1055/s-2008-1043059.
6
Post-exercise gastric emptying of carbohydrate solutions determined using the 13C acetate breath test.使用13C醋酸呼气试验测定运动后碳水化合物溶液的胃排空情况。
Eur J Appl Physiol Occup Physiol. 1995;71(4):306-10. doi: 10.1007/BF00240409.
7
The [13C]acetate breath test accurately reflects gastric emptying of liquids in both liquid and semisolid test meals.[13C]乙酸呼气试验能准确反映液体和半固体试验餐中液体的胃排空情况。
Gastroenterology. 1995 Apr;108(4):1048-55. doi: 10.1016/0016-5085(95)90202-3.
8
Gastric secretion does not affect the reliability of the 13C-acetate breath test: A validation of the 13C-acetate breath test by magnetic resonance imaging.胃分泌不会影响 13C-乙酸呼气试验的可靠性:磁共振成像对 13C-乙酸呼气试验的验证。
Neurogastroenterol Motil. 2013 Feb;25(2):176-e87. doi: 10.1111/nmo.12025. Epub 2012 Oct 16.
9
Influence of cisapride on gastric emptying of solids and liquids monitored by 13C breath tests.西沙必利对通过¹³C呼气试验监测的固体和液体胃排空的影响。
Dig Dis Sci. 1995 Oct;40(10):2200-6. doi: 10.1007/BF02209007.
10
Gastric emptying of a solid-liquid meal measured with 13C octanoic acid breath test and real-time ultrasonography: a comparative study.用13C辛酸呼气试验和实时超声检查测量固体-液体餐的胃排空:一项比较研究。
Am J Gastroenterol. 2000 Nov;95(11):3097-100. doi: 10.1111/j.1572-0241.2000.03255.x.

引用本文的文献

1
Aperitif effects on gastric emptying: a crossover study using continuous real-time 13C breath test (BreathID System).开胃酒对胃排空的影响:一项使用连续实时13C呼气试验(BreathID系统)的交叉研究。
Dig Dis Sci. 2009 Apr;54(4):816-8. doi: 10.1007/s10620-008-0427-3. Epub 2008 Aug 9.