Suppr超能文献

在高眼压治疗研究中,中央角膜厚度与局部降眼压药物治疗后测得的眼压反应

Central corneal thickness and measured IOP response to topical ocular hypotensive medication in the Ocular Hypertension Treatment Study.

作者信息

Brandt James D, Beiser Julia A, Gordon Mae O, Kass Michael A

机构信息

Department of Ophthalmology, University of California, Davis, Sacramento, California, USA.

出版信息

Am J Ophthalmol. 2004 Nov;138(5):717-22. doi: 10.1016/j.ajo.2004.07.036.

Abstract

PURPOSE

To determine whether central corneal thickness (CCT) correlates with measured intraocular pressure (IOP) response to topical ocular hypotensive medication in the Ocular Hypertension Treatment Study (OHTS).

DESIGN

Prospective randomized clinical trial.

METHODS

Intraocular pressure measurements were performed by Goldmann applanation tonometry. Central corneal thickness was measured by ultrasonic pachymetry. The following indicators of IOP response to topical ocular hypotensive medication were examined: (1) IOP after an initial four- to six-week one-eyed therapeutic trial of a nonselective beta-blocker (N = 549) or a prostaglandin analog (N = 201); (2) the mean IOP response during 12 to 60 months of follow-up among medication participants (N = 689); (3) the percentage of follow-up visits at which both eyes met the treatment goal; (4). the total number of different medications prescribed to reach treatment goal; and (5) the total number of different medications prescribed multiplied by the number of months each medication was prescribed.

RESULTS

Central corneal thickness was inversely related to the IOP response after the initial one-eyed therapeutic trial and during 12 to 60 months of follow-up (P < .05). Mean CCT was not correlated with the number of different medications prescribed during follow-up, the total medication-months, or the percentage of visits at which IOP target was met.

CONCLUSIONS

Individuals with thicker corneas had smaller measured IOP responses to ocular hypotensive medication than those with normal or thin corneas. We believe that CCT measurements may be useful in patient management and in interpreting clinical trials of ocular hypotensive medication.

摘要

目的

在高眼压治疗研究(OHTS)中确定中央角膜厚度(CCT)与局部降眼压药物治疗后测量的眼压(IOP)反应是否相关。

设计

前瞻性随机临床试验。

方法

采用Goldmann压平眼压计测量眼压。通过超声测厚法测量中央角膜厚度。检查以下局部降眼压药物治疗后眼压反应的指标:(1)在对非选择性β受体阻滞剂(N = 549)或前列腺素类似物(N = 201)进行为期4至6周的单眼治疗试验后的眼压;(2)药物治疗参与者在12至60个月随访期间的平均眼压反应(N = 689);(3)双眼达到治疗目标的随访次数百分比;(4)为达到治疗目标所开具的不同药物的总数;(5)所开具的不同药物总数乘以每种药物开具的月数。

结果

在最初的单眼治疗试验后以及12至60个月的随访期间,中央角膜厚度与眼压反应呈负相关(P <.05)。平均中央角膜厚度与随访期间开具的不同药物数量、药物总月数或眼压目标达成的随访次数百分比无关。

结论

角膜较厚的个体与角膜正常或较薄的个体相比,测量到的降眼压药物眼压反应较小。我们认为中央角膜厚度测量可能有助于患者管理以及解释降眼压药物的临床试验。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验