Sensi Luis Guilherme, Marson Fabiano Carlos, Monteiro Sylvio, Baratieri Luiz Narciso, Caldeira de Andrada Mauro Amaral
Department of Operative Dentistry, Universidade Federal de Santa Catarina, Florianópolis, Brazil.
J Contemp Dent Pract. 2004 Nov 15;5(4):32-41.
The purpose of this in vitro study was to investigate the microleakage at dentin margins of a flowable resin composite associated with an adhesive, either light cured separately or co-cured, in Class V cavities.
Twenty four recently extracted human molars were prepared with standardized box-shaped Class V cavities of 3.0 mm (mesial-distal), 2.0 mm (occlusal-gingival), and 2.0 mm depth with margins located on enamel and dentin/cementum on the buccal or lingual surfaces. The cavities were randomly assigned into three groups (n=8): Group I - Single Bond + Filtek Z250 (control); Group II - Single Bond + Filtek Flow (light cured separately) + Filtek Z250; and Group III - Single Bond + Filtek Flow co-cured (light cured simultaneously) + Filtek Z250. After being immersed in tap water for 24 h, the specimens were thermocycled (1000x, 5 degrees -55 degrees C, 30 sec dwell time) and immersed in a 0.5% basic fuchsine solution for 24 h. The restorations were sectioned longitudinally and gingival margins were evaluated for microleakage using a 0-4 scale. Data were subjected to the Kruskal-Wallis test at p<0.05.
A statistically significant difference at p = 0.0044 between Groups 1 and 3 and Groups 2 and 3 was observed. Although Group 2 performed slightly better than Group 1, no significant difference was observed.
The use of a flowable resin composite cured simultaneously with an adhesive yielded the worst results in this study. As no statistical differences were seen between Groups 1 and 2, the use of a flowable composite as a means of minimizing microleakage at dentin margins may be questioned.
本体外研究的目的是调查在V类洞型中,与一种粘合剂联合使用的可流动树脂复合材料在牙本质边缘的微渗漏情况,该复合材料可单独光固化或共同固化。
选取24颗近期拔除的人类磨牙,制备标准化的盒状V类洞型,洞型尺寸为近远中径3.0mm、咬合龈向径2.0mm、深度2.0mm,洞缘位于颊面或舌面的釉质以及牙本质/牙骨质上。将洞型随机分为三组(n = 8):第一组——单键粘结剂+Filtek Z250(对照组);第二组——单键粘结剂+Filtek Flow(单独光固化)+Filtek Z250;第三组——单键粘结剂+Filtek Flow共同固化(同时光固化)+Filtek Z250。将标本在自来水中浸泡24小时后,进行热循环(1000次循环,5℃-55℃,保持时间30秒),然后浸泡在0.5%的碱性品红溶液中24小时。沿纵向切开修复体,使用0-4级评分评估牙龈边缘的微渗漏情况。数据采用Kruskal-Wallis检验,p<0.05。
在第一组与第三组以及第二组与第三组之间观察到p = 0.0044的统计学显著差异。虽然第二组的表现略优于第一组,但未观察到显著差异。
在本研究中,可流动树脂复合材料与粘合剂同时固化产生了最差的结果。由于第一组和第二组之间未观察到统计学差异,因此使用可流动复合材料作为减少牙本质边缘微渗漏的方法可能值得质疑。