The Thulium fiber laser may have several advantages over current urology lasers, including smaller size, more efficient operation, improved spatial beam quality, more precise tissue incision, and operation in pulsed or continuous-wave modes. Previous laser-tissue interaction studies utilizing the Thulium fiber laser have been limited to laser powers of less than 5 W, restricting potential medical applications. This study describes the preliminary testing of a high-power Thulium fiber laser for vaporization of the canine prostate, ex vivo.
STUDY DESIGN/MATERIALS AND METHODS: A continuous-wave, 110-W Thulium fiber laser operating at a wavelength of 1.91 microm, delivered 88.5+/-2.3 W of power through a 600-microm-core silica fiber for non-contact vaporization of canine prostates (n = 6).
The Thulium fiber laser vaporized prostate tissue at a rate of 0.83+/-0.11 g/minute. The thermal coagulation zone measured 500-2,000 microm, demonstrating the potential for hemostasis.
The high-power Thulium fiber laser is capable of rapid vaporization and coagulation of the prostate. In vivo animal studies are currently being planned for evaluation of the Thulium fiber laser for potential treatment of benign prostate hyperplasia (BPH).
相较于当前的泌尿外科激光设备,铥光纤激光器可能具有多项优势,包括体积更小、运行效率更高、空间光束质量更佳、组织切口更精确,以及可在脉冲或连续波模式下运行。此前利用铥光纤激光器进行的激光与组织相互作用研究仅限于激光功率低于5瓦的情况,这限制了其潜在的医学应用。本研究描述了一种高功率铥光纤激光器在体外对犬前列腺进行汽化的初步测试。
研究设计/材料与方法:一台连续波、功率为110瓦的铥光纤激光器,波长为1.91微米,通过一根600微米芯径的石英光纤传输88.5±2.3瓦的功率,用于对犬前列腺(n = 6)进行非接触式汽化。
铥光纤激光器汽化前列腺组织的速率为0.83±0.11克/分钟。热凝固区测量值为500 - 2000微米,显示出止血的潜力。
高功率铥光纤激光器能够快速汽化和凝固前列腺组织。目前正在计划进行体内动物研究,以评估铥光纤激光器用于治疗良性前列腺增生(BPH)的潜力。