Redl H, Bahrami S, Leichtfried G, Schlag G
Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Vienna, Austria.
Clin Chem. 1992 May;38(5):764-5.
Commercially available blood-collection tubes may be contaminated with endotoxin (315 +/- 95 pg/tube) and could therefore be unsuitable for blood collection for endotoxin measurement. Plasma separation and storage are a potential source of contamination. To avoid contamination and error, we have developed new blood collection tubes that contain heparin free of endotoxin (LPS) and a gel to separate plasma and blood cells. The LPS content is less than 4 pg/tube. Samples can be stored and frozen without plasma withdrawal to preclude contamination. LPS recovery experiments have shown that the new blood-collection tubes do not bind LPS to the separation gel or vial wall. With these tubes, in vitro formation of tumor necrosis factor (404 +/- 163 ng/L in standard tubes vs less than 40 ng/L in special collection tubes) is minimized.
市售采血管可能被内毒素污染(315±95 pg/管),因此可能不适合用于采集血液进行内毒素测量。血浆分离和储存是潜在的污染源。为避免污染和误差,我们开发了新型采血管,其含有不含内毒素(脂多糖)的肝素和用于分离血浆与血细胞的凝胶。脂多糖含量低于4 pg/管。样品无需抽取血浆即可储存和冷冻,以防止污染。脂多糖回收实验表明,新型采血管不会使脂多糖结合到分离凝胶或瓶壁上。使用这些采血管,肿瘤坏死因子的体外形成量降至最低(标准管中为404±163 ng/L,特殊采血管中低于40 ng/L)。