Suppr超能文献

健康年轻志愿者在进行低强度运动时,直立式与卧式自行车测力计的心血管反应比较:使用美国运动医学学会(ACSM)代谢方程计算摄氧量的可靠性评估

Comparison of cardiovascular responses between upright and recumbent cycle ergometers in healthy young volunteers performing low-intensity exercise: assessment of reliability of the oxygen uptake calculated by using the ACSM metabolic equation.

作者信息

Saitoh Masakazu, Matsunaga Atsuhiko, Kamiya Kentaro, Ogura Misao N, Sakamoto Junko, Yonezawa Ryusuke, Kasahara Yusuke, Watanabe Hiroyuki, Masuda Takashi

机构信息

Department of Angiology and Cardiology, Graduate School of Medical Sciences, Kanagawa, Japan.

出版信息

Arch Phys Med Rehabil. 2005 May;86(5):1024-9. doi: 10.1016/j.apmr.2004.09.030.

Abstract

OBJECTIVES

To clarify (1) differences in cardiovascular response during low-intensity exercise in the upright versus the recumbent position, and (2) whether the oxygen uptake (V o 2 ) calculated by the American College of Sports Medicine (ACSM) metabolic equation reflects the actual V o 2 at low-intensity testing.

DESIGN

Repeated-measures comparison study.

SETTING

University research laboratory.

PARTICIPANTS

Thirty-one healthy, young volunteers (age, 23+/-2y).

INTERVENTIONS

Not applicable.

MAIN OUTCOME MEASURES

Blood pressure, rate pressure product (RPP), V o 2 , oxygen pulse, carbon dioxide output (V co 2 ), and ventilatory equivalent (V e ) were measured during graded exercise testing using upright and recumbent cycle ergometers. The estimated V o 2 was calculated by using the ACSM metabolic equation.

RESULTS

Systolic blood pressure, RPP, V o 2 , oxygen pulse, V co 2 , and V e at 15 or 30W were significantly higher in the recumbent position than in the upright one ( P <.05), however, no significant differences were observed at 50 and 70W. The estimated V o 2 during exercise was significantly higher than the actual one, at every level of intensity, from 15 to 70W ( P <.05).

CONCLUSIONS

Cardiovascular responses should be carefully monitored even during low-intensity exercise using a recumbent cycle ergometer. The V o 2 estimated using the ACSM metabolic equation did not reflect the actual V o 2 during low-intensity exercise at 70W or less.

摘要

目的

明确(1)在低强度运动中,直立位与卧位时心血管反应的差异;(2)美国运动医学学会(ACSM)代谢方程计算出的摄氧量(V o 2 )是否能反映低强度测试时的实际V o 2 。

设计

重复测量比较研究。

设置

大学研究实验室。

参与者

31名健康的年轻志愿者(年龄23±2岁)。

干预措施

不适用。

主要观察指标

在使用直立式和卧式自行车测力计进行分级运动测试期间,测量血压、心率血压乘积(RPP)、V o 2 、氧脉搏、二氧化碳排出量(V co 2 )和通气当量(V e )。使用ACSM代谢方程计算估计的V o 2 。

结果

在15或30W时,卧位的收缩压、RPP、V o 2 、氧脉搏、V co 2 和V e 显著高于直立位(P<.05),然而,在50和70W时未观察到显著差异。在15至70W的每个强度水平,运动期间估计的V o 2 均显著高于实际值(P<.05)。

结论

即使在使用卧式自行车测力计进行低强度运动时,也应仔细监测心血管反应。使用ACSM代谢方程估计的V o 2 在70W及以下的低强度运动期间不能反映实际的V o 2 。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验