用于在批量和流动模式下测定纯溶液和药物制剂中莨菪碱的聚氯乙烯膜离子选择性电极。

PVC membrane ion-selective electrodes for the determination of Hyoscyamine in pure solution and in pharmaceutical preparations under batch and flow modes.

作者信息

Badawy Sayed S, Issa Yousry M, Mutair Ali A

机构信息

Chemistry Department, Faculty of Science, Cairo University, Giza, Egypt.

出版信息

J Pharm Biomed Anal. 2005 Sep 1;39(1-2):117-24. doi: 10.1016/j.jpba.2005.03.025.

Abstract

New PVC membrane electrodes selective for the determination of hyoscyamine ion (Hy(+)) based on hyoscyamine tetraphenylborate (Hy-TPB) or hyoscyamine phosphotungstate (Hy-PT) ion-exchangers as electroactive materials are described. The electrodes show a linear response for Hy(+) over the concentration range of 1.00 x 10(-5) to 1.26 x 10(-2) mol L(-1) and 1.00 x 10(-4) to 1.00 x 10(-2) mol L(-1) in case of Hy-TPB electrode applying batch and flow injection analysis (FIA), respectively, and 1.00 x 10(-5) to 4.52 x 10(-3) mol L(-1) and 6.31 x 10(-5) to 1.00 x 10(-2) mol L(-1) in case of Hy-PT electrode for batch and FIA, respectively. The lower detection limits are 3.90 x 10(-6) and 4.51 x 10(-6) at 25 degrees C for Hy-TPB and Hy-PT electrodes, respectively. The electrodes posses near Nernstian slopes of 56.5 and 57.8 mV/decade for Hy-TPB and Hy-PT electrodes, respectively, and a fast potential response of < or =20 s which is almost constant over a pH range of 3-10. Selectivity coefficient data for some common inorganic cations, sugars, amino acids and the components, other than hyoscyamine, of the mixed drugs investigated show negligible interference. The electrodes have been applied to the potentiometric determination of hyoscyamine in pure solution and in pharmaceutical preparations under batch and FIA conditions and as end point indicator electrode for the determination of hyoscyanine using potentiometric titration. For the concentrations (1.08 x 10(-5) mol L(-1) to 3.16 x 10(-3) mol L(-1)) an average recovery of 99.95% with relative standard deviation of 0.63% has been achieved. The effect of temperature on the electrodes was also studied.

摘要

本文描述了一种新型聚氯乙烯(PVC)膜电极,该电极基于氢溴酸东莨菪碱四苯基硼酸盐(Hy - TPB)或氢溴酸东莨菪碱磷钨酸盐(Hy - PT)离子交换剂作为电活性材料,用于选择性测定东莨菪碱离子(Hy(+))。对于Hy - TPB电极,在采用分批分析和流动注射分析(FIA)时,Hy(+)在1.00×10(-5)至1.26×10(-2) mol L(-1)以及1.00×10(-4)至1.00×10(-2) mol L(-1)浓度范围内呈现线性响应;对于Hy - PT电极,在分批分析和FIA时,Hy(+)分别在1.00×10(-5)至4.52×10(-3) mol L(-1)以及6.31×10(-5)至1.00×10(-2) mol L(-1)浓度范围内呈现线性响应。在25℃时,Hy - TPB和Hy - PT电极的最低检测限分别为3.90×10(-6)和4.51×10(-6)。Hy - TPB和Hy - PT电极的能斯特斜率分别接近56.5和57.8 mV/十倍浓度变化,且电位响应快速,小于或等于20秒,在pH值3 - 10范围内几乎保持恒定。对于一些常见无机阳离子、糖类、氨基酸以及所研究混合药物中东莨菪碱以外的成分,其选择性系数数据显示干扰可忽略不计。该电极已应用于在分批和FIA条件下对纯溶液和药物制剂中东莨菪碱的电位测定,以及作为电位滴定法测定氢溴酸东莨菪碱的终点指示电极。对于浓度范围为(1.08×10(-5) mol L(-1)至3.16×10(-3) mol L(-1)),平均回收率达到99.95%,相对标准偏差为0.63%。同时还研究了温度对电极的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验