808纳米二极管激光治疗大隐静脉的即刻效应:形态学研究及临床意义

The immediate effects of endovenous diode 808-nm laser in the greater saphenous vein: morphologic study and clinical implications.

作者信息

Corcos Leonardo, Dini Sergio, De Anna Dino, Marangoni Ovidio, Ferlaino Elio, Procacci Tiziana, Spina Tommaso, Dini Mario

机构信息

Postgraduate School of Vascular Surgery, University of Udine, Italy.

出版信息

J Vasc Surg. 2005 Jun;41(6):1018-24; discussion 1025. doi: 10.1016/j.jvs.2005.03.002.

Abstract

BACKGROUND

We conducted this study to evaluate the immediate venous morphologic alterations produced in the great saphenous veins by the endovenous diode 808-nm laser used for the treatment of superficial venous insufficiency and varicose veins of the lower limbs and to clarify the clinical implications of the histologic findings.

METHODS

Chosen for the study were 24 limbs of 16 patients with CEAP classification 3 to 6, ultrasound-documented greater saphenous insufficiency, and venous diameters between 3.9 mm and 17 mm (mean, 8.04 mm) without phlebitis, saphenous aneurysms, congenital malformations, or deep venous insufficiency. All limbs underwent surgical saphenofemoral disconnection, and the greater saphenous vein was treated with an endovenous diode 808-nm laser by continuous emission at 8 to 12 W and variable retraction speed (</>1 mm/s). Spinal or local, but not tumescent, anesthesia was used. Twenty-nine specimens (3 to 5 cm long) of 24 proximal greater saphenous and five anterior accessory saphenous veins were excised and studied by light microscopy for diameter and thickness of the venous wall, extent of injury into the intima, media, and adventitia, as well as penetration of thermal damage.

RESULTS

The histologic evaluation showed thermal injury to the intima in all specimens and full-thickness intimal injury in 22 specimens (75%); the average penetration of thermal injury in 29 specimens was 194.40 microm (range, 10 to 900 microm; 14.61% of the mean wall thickness); complete intimal circumference injury occurred in 8 specimen veins <10 mm in diameter (27.5%), full thickness damage in 6 (20.7%), and perforation in 2 (6.9%).

CONCLUSIONS

Saphenous ablation using 808-nm laser by variable retraction speed, combined with saphenofemoral interruption, leads to sufficient vein wall injury to assure venous occlusion. Full thickness thermal injury or perforation is infrequent. Optimal results can be obtained in veins <10 mm in diameter.

摘要

背景

我们开展这项研究,旨在评估用于治疗下肢浅静脉功能不全和静脉曲张的静脉腔内808纳米二极管激光对大隐静脉造成的即时静脉形态学改变,并阐明组织学研究结果的临床意义。

方法

选取16例CEAP分级为3至6级、超声检查证实存在大隐静脉功能不全、静脉直径在3.9毫米至17毫米之间(平均8.04毫米)、无静脉炎、大隐静脉瘤、先天性畸形或深静脉功能不全的患者的24条肢体。所有肢体均接受了大隐静脉-股静脉离断术,并用静脉腔内808纳米二极管激光以8至12瓦的连续发射功率和可变回撤速度(</>1毫米/秒)治疗大隐静脉。采用脊髓麻醉或局部麻醉,但不采用肿胀麻醉。切除24条近端大隐静脉和5条前副大隐静脉的29个标本(长3至5厘米),通过光学显微镜研究静脉壁的直径和厚度、内膜、中膜和外膜的损伤程度以及热损伤的穿透情况。

结果

组织学评估显示,所有标本的内膜均有热损伤,22个标本(75%)出现全层内膜损伤;29个标本的热损伤平均穿透深度为194.40微米(范围为10至900微米;占平均壁厚的14.61%);8条直径<10毫米的标本静脉出现完整的内膜圆周损伤(27.5%),6条出现全层损伤(20.7%),2条出现穿孔(6.9%)。

结论

采用可变回撤速度的808纳米激光进行大隐静脉消融,并结合大隐静脉-股静脉离断术,可导致足够的静脉壁损伤以确保静脉闭塞。全层热损伤或穿孔并不常见。直径<10毫米的静脉可获得最佳效果。