• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Prospective evaluation of the contraction stress and nonstress tests in the management of post-term pregnancy.

作者信息

Druzin M L, Karver M L, Wagner W, Hutson J M, Waltner A, Kogut E

机构信息

Department of Obstetrics and Gynecology, New York Hospital-Cornell Medical Center, New York.

出版信息

Surg Gynecol Obstet. 1992 Jun;174(6):507-12.

PMID:1595028
Abstract

Eight hundred and nineteen patients were evaluated at greater than or equal to 280 days' gestation. All patients underwent nonstress test (NST) and breast stimulation to induce contraction stress test (CST), except where contraindicated. If CST was nonqualifying (less than three contractions per ten minutes), Pitocin (oxytocin) was used to complete the CST if there was a nonreactive NST. Delivery was instituted for any abnormal CST, even with a reactive NST, based on the last test within seven days of delivery. There were 747 reactive NST and 72 nonreactive NST. Breast stimulation for CST was done in 655 instances--315 (48 per cent) had nonqualifying CST and 340 (52 per cent) had qualifying CST. There was an increased incidence of induction in the nonqualifying CST group and abnormal CST group. There were no statistically significant differences in perinatal outcomes in the group with reactive NST, irrespective of the CST result. There were no antepartum fetal deaths.

摘要

相似文献

1
Prospective evaluation of the contraction stress and nonstress tests in the management of post-term pregnancy.
Surg Gynecol Obstet. 1992 Jun;174(6):507-12.
2
Comparative study of stressed and nonstressed antepartum fetal heart rate testing.有应激与无应激产前胎儿心率检测的对比研究
Obstet Gynecol. 1981 Mar;57(3):320-4.
3
An active management approach to the postdate fetus with a reactive nonstress test and fetal heart rate decelerations.一种针对过期胎儿的积极管理方法,伴有反应型无应激试验和胎儿心率减速。
Obstet Gynecol. 1987 Oct;70(4):636-40.
4
Antepartum fetal heart testing: a clinical appraisal.产前胎儿心脏检测:临床评估
Obstet Gynecol. 1984 Jan;63(1):48-51.
5
Assessment of fetal well-being using the nonstress test in the home setting.在家中使用无应激试验评估胎儿健康状况。
Obstet Gynecol. 1994 Sep;84(3):424-6.
6
The value of a negative antepartum test: contraction stress test and modified biophysical profile.
Obstet Gynecol. 1994 Aug;84(2):231-4.
7
Antepartum fetal heart rate testing. I. Evolution of the nonstress test.产前胎儿心率检测。一、无应激试验的演变
Am J Obstet Gynecol. 1979 Jan 1;133(1):29-33. doi: 10.1016/0002-9378(79)90406-x.
8
Antepartum heart rate testing in diabetic pregnancy.糖尿病妊娠的产前心率检测
J Reprod Med. 1985 Jul;30(7):515-8.
9
Correlation of nonstressed fetal heart rate with sequential contraction stress test.无应激胎儿心率与连续宫缩应激试验的相关性
Obstet Gynecol. 1980 May;55(5):612-6.
10
Does Doppler-detected fetal movement decrease the incidence of nonreactive nonstress tests?经多普勒检测的胎儿运动能否降低无反应型无应激试验的发生率?
Obstet Gynecol. 1993 Dec;82(6):999-1003.