在膝关节置换术中实现韧带稳定性和股骨正确的旋转对线:一项使用内侧旋转铰链膝关节的研究

Achieving ligament stability and correct rotational alignment of the femur in knee arthroplasty: a study using the Medial Pivot knee.

作者信息

Shakespeare David, Kinzel Vera, Ledger Michael

机构信息

Department of Orthopaedics, Warwick Hospital, Lakin Road, Warwick, UK.

出版信息

Knee. 2005 Dec;12(6):419-23. doi: 10.1016/j.knee.2005.03.002. Epub 2005 Jun 20.

Abstract

In a series of 90 Medial Pivot arthroplasties rotational alignment of the femur was achieved by provisionally reconstructing the lateral side of the joint and tensioning the medial side with feeler gauges. Axial CT scans were employed to measure the rotational alignment relative to surgical epicondylar axis. In valgus knees the cutting block was externally rotated to adjust for posterolateral bone loss. The mean rotational alignment of the femur was 0.6 degrees of external rotation (S.D. 1.3, range 3 degrees of ER to 4 degrees of IR). The mean laxity of the medial ligament was 1 mm in flexion (SD 1, range 0-5 mm) and 0.5 mm in flexion (S.D. 0.5, range 0-2 mm) In those knees in which the medial ligament had been released the CT alignment was perfect, but when internally rotated against the hip 3-4 mm of gapping was noted. In valgus knees the mean rotation of the femoral component was 0.8 degrees of internal rotation (S.D. 1.5, range 1 degrees of IR to 4 degrees of ER). In spite of externally rotating the cutting block there was still a tendency to internally rotate the femur in some knees. This simple technique achieves the two goals of ligament stability and correct rotational alignment in a high proportion of cases. It may be applicable to any instrument system which employs posterior referencing.

摘要

在一系列90例内侧旋转铰链膝关节置换术中,通过临时重建关节外侧并使用塞尺张紧内侧来实现股骨的旋转对线。采用轴向CT扫描测量相对于手术上髁轴的旋转对线。对于外翻膝,将截骨模块向外旋转以调整后外侧骨缺损。股骨的平均旋转对线为0.6°外旋(标准差1.3,范围为3°外旋至4°内旋)。内侧韧带在屈膝时的平均松弛度为1mm(标准差1,范围为0 - 5mm),在伸膝时为0.5mm(标准差0.5,范围为0 - 2mm)。在那些内侧韧带已被松解的膝关节中,CT对线是完美的,但当髋关节内旋时,会出现3 - 4mm的间隙。在外翻膝中,股骨组件的平均旋转为0.8°内旋(标准差1.5,范围为1°内旋至4°外旋)。尽管截骨模块向外旋转,但在一些膝关节中仍有股骨内旋的趋势。这种简单的技术在很大比例的病例中实现了韧带稳定性和正确旋转对线这两个目标。它可能适用于任何采用后方参考的器械系统。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验