Shimizu Tsuyoshi, Suesada Hiroyuki, Cho Masaaki, Ito Shigeki, Ikeda Katsusuke, Ishimaru Shin
Department of Surgery II, Tokyo Medical University, Tokyo, Japan.
Ann Thorac Surg. 2005 Jul;80(1):124-30. doi: 10.1016/j.athoracsur.2005.02.013.
Native flow competition is a significant factor affecting bypass graft patency. The objective of this study was to compare the effect of competitive flow on conduit flow dynamics in the gastroepiploic artery (GEA) and the saphenous vein graft (SVG).
In 51 patents, 23 GEAs (in-situ grafts) and 28 SVGs (aortocoronary grafts) were examined using a Doppler-tipped guidewire during coronary angiography after coronary artery bypass. Graft flow volume at rest and maximum graft flow volume during hyperemia were calculated from graft diameter and average peak velocity at rest and maximum average peak velocity induced by papaverine hydrochloride injection. Grafts were classified according to the grade of native coronary artery stenosis; group S (14 GEAs and 16 SVGs) displayed over 75% stenosis and group M (9 GEAs and 12 SVGs) exhibited over 50% up to 75% stenosis.
In group S, no difference in flow volume was apparent between the GEA and the SVG at rest (36+/- 17 vs 42 +/- 16) and during hyperemia (78 +/- 30 vs 88 +/- 28). In group M, flow volume of the GEA was significantly lower than that of the SVG at rest (17 +/- 11 vs 38 +/- 12; p = 0.029) and during hyperemia (32 +/- 19 vs 94 +/- 46; p = 0.001).
These data suggest that in intermediate coronary stenosis, GEA flow is compromised by native flow competition, whereas the SVG flow dynamics is maintained. However, the GEA can provide comparable flow capacity to the SVG and will achieve good surgical results when target coronary artery selection is appropriate.
自身血流竞争是影响旁路移植血管通畅性的一个重要因素。本研究的目的是比较竞争血流对胃网膜动脉(GEA)和大隐静脉移植血管(SVG)的管道血流动力学的影响。
在51例患者中,23例GEA(原位移植血管)和28例SVG(主动脉冠状动脉移植血管)在冠状动脉旁路移植术后行冠状动脉造影时使用多普勒探头导丝进行检查。根据移植血管直径以及静息时的平均峰值速度和注射盐酸罂粟碱诱导的最大平均峰值速度,计算静息时的移植血管血流量和充血时的最大移植血管血流量。根据自身冠状动脉狭窄程度对移植血管进行分类;S组(14例GEA和16例SVG)显示狭窄超过75%,M组(9例GEA和12例SVG)显示狭窄超过50%至75%。
在S组中,GEA和SVG在静息时(36±17 vs 42±16)和充血时(78±30 vs 88±28)的血流量无明显差异。在M组中,GEA在静息时(17±11 vs 38±12;p = 0.029)和充血时(32±19 vs 94±46;p = 0.001)的血流量显著低于SVG。
这些数据表明,在中度冠状动脉狭窄时,GEA血流受到自身血流竞争的影响,而SVG的血流动力学则得以维持。然而,GEA可提供与SVG相当的血流能力,并且在选择合适的靶冠状动脉时将获得良好的手术效果。