As a preclinical study, we evaluated the ability of hydroxyapatite and titanium on zirconia (HTOZ) to bond to bone under load-bearing conditions in animal experiments. HTOZ, HA, and Ti on Co-Cr alloy (HTOC) and Ti on Co-Cr alloy (TOC) were implanted into the weight-bearing portion of the femoral condyles of nine beagle dogs. Femurs were extracted 4, 12, and 52 weeks after implantation and examined mechanically by pullout testing, and histologically by toluidine blue staining, SEM, and calculation of the affinity index. The interfacial shear strengths (mean+/-SD) of the HTOZ, HTOC, and TOC groups were 4.42+/-0.453, 3.90+/-0.903, and 4.08+/-0.790 MPa at 4 weeks; 6.82+/-2.64, 6.00+/-1.88, and 6.63+/-1.63 MPa at 12 weeks; and 13.98+/-1.94, 11.95+/-1.51, and 10.78+/-0.83 MPa at 52 weeks. There were no significant differences in the interfacial shear strengths between the three groups at any time. Affinity indices (mean+/-SD) obtained from SEM images of the HTOZ, HTOC, and TOC groups were 49.6+/-6.52%, 43.3+/-10.43%, and 23.7+/-3.95% at 4 weeks; 55.0+/-6.72%, 51.5+/-3.07%, and 28.6+/-4.09% at 12 weeks; and 59.1+/-6.73%, 63.0+/-6.40%, and 34.3+/-6.72% at 52 weeks. HA-coated implants (HTOZ, HTOC) had significantly higher affinity indices than non-HA-coated implants (TOC) at all times. HTOZ has the ability to bond to bone equivalent to HTOC and TOC. HTOZ is an excellent material for components of cementless joint prostheses.
作为一项临床前研究,我们在动物实验中评估了羟基磷灰石和氧化锆上的钛(HTOZ)在承重条件下与骨结合的能力。将HTOZ、羟基磷灰石和钴铬合金上的钛(HTOC)以及钴铬合金上的钛(TOC)植入9只比格犬股骨髁的承重部位。植入后4周、12周和52周取出股骨,通过拔出试验进行力学检查,并通过甲苯胺蓝染色、扫描电子显微镜和亲和指数计算进行组织学检查。HTOZ、HTOC和TOC组的界面剪切强度(平均值±标准差)在4周时分别为4.42±0.453、3.90±0.903和4.08±0.790MPa;在12周时分别为6.82±2.64、6.00±1.88和6.63±1.63MPa;在52周时分别为13.98±1.94、11.95±1.51和10.78±0.83MPa。三组在任何时间的界面剪切强度均无显著差异。从HTOZ、HTOC和TOC组的扫描电子显微镜图像获得的亲和指数(平均值±标准差)在4周时分别为49.6±6.52%、43.3±10.43%和23.7±3.95%;在12周时分别为55.0±6.72%、51.5±3.07%和28.6±4.09%;在52周时分别为59.1±6.73%、63.0±6.40%和34.3±6.72%。在所有时间,涂有羟基磷灰石的植入物(HTOZ、HTOC)的亲和指数均显著高于未涂覆羟基磷灰石的植入物(TOC)。HTOZ与骨结合的能力等同于HTOC和TOC。HTOZ是一种用于非骨水泥关节假体部件的优良材料。