Hathout G, Lufkin R B, Jabour B, Andrews J, Castro D
Department of Radiological Sciences, UCLA Medical Center 90024-1721.
J Magn Reson Imaging. 1992 Jan-Feb;2(1):93-4. doi: 10.1002/jmri.1880020117.
Published reports of magnetic resonance (MR)-guided needle biopsy have involved low- and mid-field-strength systems because of the concern of needle artifact and risk of increased needle torque at higher field strengths. To the authors' knowledge, this is the first report of a high-field-strength (1.5-T) system used to guide aspiration cytology in the head and neck in a patient. The procedure was successfully accomplished without additional needle torque or substantial increase in image artifact relative to lower-field-strength imaging.