Development and implementation of a real-time control strategy for the sewer system of the city of Vienna.

作者信息

Fuchs L, Beeneken T

机构信息

Institute for technical scientific hydrology, Engelbosteler Damm 22, D-30167 Hannover.

出版信息

Water Sci Technol. 2005;52(5):187-94.

PMID:16248195
Abstract

The paper describes the realization of a real-time control for the Vienna sewer system. The project is scheduled for completion for 2004. The 3.5 year project comprises all planning stages starting with the recording of data up to the planning of measuring and controlling units. The concrete steps of the planning stages are explained. A measuring system including 25 rainfall measurements, 40 flow measurements and 20 water level measurements is implemented as an online system. This measuring system is designed to achieve two objectives, on the one hand the real-time control and on the other hand the calibration of the model that is used for the hydrodynamic sewer system simulation. The approx. 53,000 pipes have served to generate a coarse network of no more than approx. 2600 pipes. The area data were derived with high accuracy from available aerial photograph interpretations. With simulation runs of a rule-based control software the system operation was examined. A self-learning system will improve the rule basis. A forecasting model that uses weather observation radar will additionally influence the controlling decisions. The findings from the investigations are immediately considered in the planning of measuring and control units. The simulated results for the first phase of implementation, which demonstrate the benefit of RTC for the Vienna sewer system, are explained.

摘要

相似文献

1
Development and implementation of a real-time control strategy for the sewer system of the city of Vienna.
Water Sci Technol. 2005;52(5):187-94.
2
Development of the real-time control (RTC) system for Tokyo sewage system.东京污水系统实时控制系统的开发。
Water Sci Technol. 2005;51(2):213-20.
3
Current state and development of the real-time control of the Berlin sewage system.柏林污水系统实时控制的现状与发展
Water Sci Technol. 2005;52(12):181-7.
4
Long-term pollution simulation in combined sewer networks.合流制排水管网的长期污染模拟
Water Sci Technol. 2001;43(7):83-9.
5
Consideration of online rainfall measurement and nowcasting for RTC of the combined sewage system.考虑将在线降雨测量和临近预报用于合流制排水系统的实时控制。
Water Sci Technol. 2008;57(11):1799-804. doi: 10.2166/wst.2008.289.
6
Nowcasting of rainfall and of combined sewage flow in urban drainage systems.城市排水系统中降雨及混合污水流量的临近预报。
Water Sci Technol. 2009;59(6):1145-51. doi: 10.2166/wst.2009.098.
7
Integrated real-time control for a sequencing batch reactor plant and a combined sewer system.
Water Sci Technol. 2005;52(5):179-86.
8
Effects of real time control of sewer systems on treatment plant performance and receiving water quality.下水道系统实时控制对污水处理厂性能及受纳水体水质的影响。
Water Sci Technol. 2002;45(3):229-37.
9
Sewer modelling based on highly distributed calibration data sets and multi-objective auto-calibration schemes.基于高度分布式校准数据集和多目标自动校准方案的下水道建模。
Water Sci Technol. 2008;57(10):1547-54. doi: 10.2166/wst.2008.305.
10
Criteria for assessment of the operational potential of the urban wastewater system.城市污水系统运行潜力的评估标准。
Water Sci Technol. 2002;45(3):141-8.

引用本文的文献

1
A review of pollution-based real-time modelling and control for sewage systems.污水系统基于污染的实时建模与控制综述。
Heliyon. 2024 May 31;10(11):e31831. doi: 10.1016/j.heliyon.2024.e31831. eCollection 2024 Jun 15.