Durduran Turgut, Choe Regine, Yu Guoqiang, Zhou Chao, Tchou Julia C, Czerniecki Brian J, Yodh Arjun G
Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Opt Lett. 2005 Nov 1;30(21):2915-7. doi: 10.1364/ol.30.002915.
Blood flow contrast between tumor and normal tissues in patients with malignant and benign breast cancer was measured by diffuse optical correlation methods. The measurements were carried out with a hand-held optical probe that was manually scanned over the tumor-bearing breast. Increased blood flow was observed in tumor regions relative to healthy tissue, and control subjects did not exhibit significant blood flow heterogeneity. The measurements introduce a new optical contrast for diffuse optical mammography.
采用扩散光学相关方法测量了恶性和良性乳腺癌患者肿瘤组织与正常组织之间的血流对比度。测量是使用手持式光学探头进行的,该探头在患侧乳房上进行手动扫描。相对于健康组织,肿瘤区域观察到血流增加,而对照受试者未表现出明显的血流异质性。这些测量为扩散光学乳腺摄影术引入了一种新的光学对比度。