Rossiter H B, Kowalchuk J M, Whipp B J
Department of Physiology, St. George's Hospital Medical School, London, UK.
J Appl Physiol (1985). 2006 Mar;100(3):764-70. doi: 10.1152/japplphysiol.00932.2005. Epub 2005 Nov 10.
The O2 uptake (Vo2) response to ramp incremental (RI) exercise does not consistently demonstrate plateau-like behavior at the limit of tolerance, and hence the requirements for a maximum Vo2 commonly are not met, despite apparent maximum effort. We sought to determine whether an appended step exercise (SE) test at a work rate greater than that achieved in a preceding ramp test would establish the plateau criterion. Seven healthy male adults performed RI cycle ergometry (20 W/min) to the limit of tolerance, followed by 5-min recovery (20 W) and then an SE test at 105% (RISE-105) of the final work rate (WRpeak) achieved during RI. Five of these subjects also performed an RI test followed by SE at 95% WRpeak (RISE-95). Vo2 was measured breath by breath using a turbine and mass spectrometer. The average of the final 15 s of RI or SE was used to establish respective Vo2 peaks. When Vo2 peak was approached, a constant Vo2 value (e.g., a plateau) was not discernable during any RI or SE component of the tests. Although the WRpeak [mean (SD)] was higher during the SE portion [359 W (SD 31)] than during the RI portion [341 W (SD 29)] of the RISE-105, the peak Vo2 was not different [SE, 4.30 l/min (SD 0.51); RI, 4.33 l/min (SD 0.52); P=0.49; n=7]. Similarly, in the RISE-95 test, WRpeak was 310 W (SD 31) for the SE portion and 326 W (SD 32) for the RI portion, yet the peak Vo2 values were not different [SE, 4.12 l/min (SD 0.53); RI, 4.11 l/min (SD 0.48); P=0.78; n=5]. The lack of notable difference between the Vo2 peaks established at different WRpeak values in our RISE protocols provides the plateau criterion for verification of maximum Vo2 in a single test session, even when the data response profiles do not themselves evidence a plateau.
对斜坡递增(RI)运动的摄氧量(Vo2)反应在耐受极限时并不总是呈现出类似平台期的表现,因此,尽管受试者明显已竭尽全力,但通常仍无法达到最大Vo2的要求。我们试图确定,在高于先前斜坡测试所达到的工作强度下附加进行一次阶梯运动(SE)测试,是否能确立平台期标准。七名健康成年男性进行RI周期测力计测试(20瓦/分钟)至耐受极限,随后进行5分钟恢复(20瓦),然后以RI期间达到的最终工作强度(WRpeak)的105%进行SE测试(RISE - 105)。其中五名受试者还进行了一次RI测试,随后以WRpeak的95%进行SE测试(RISE - 95)。使用涡轮机和质谱仪逐 breath测量Vo2。RI或SE最后15秒的平均值用于确定各自的Vo2峰值。在测试的任何RI或SE部分,当接近Vo2峰值时,均未发现Vo2值恒定(即平台期)。尽管在RISE - 105的SE部分,WRpeak[平均值(标准差)]高于RI部分[359瓦(标准差31)对341瓦(标准差29)],但峰值Vo2并无差异[SE为4.30升/分钟(标准差0.51);RI为4.33升/分钟(标准差0.52);P = 0.49;n = 7]。同样,在RISE - 95测试中,SE部分的WRpeak为310瓦(标准差31),RI部分为326瓦(标准差32),但峰值Vo2值并无差异[SE为4.12升/分钟(标准差0.53);RI为4.11升/分钟(标准差0.48);P = 0.78;n = 5]。在我们的RISE方案中,不同WRpeak值下确立的Vo2峰值之间缺乏显著差异,这为在单次测试中验证最大Vo2提供了平台期标准,即使数据反应曲线本身并未显示出平台期。