隐形眼镜“T”仍然重要吗?

Is contact lens "T" still important?

作者信息

Huang Pochi, Zwang-Weissman Jeremy, Weissman Barry A

机构信息

Department of Organismic Biology, Ecology & Evolution, College of Letters and Science, University of California, Los Angeles, USA.

出版信息

Cont Lens Anterior Eye. 2004 Mar;27(1):9-14. doi: 10.1016/j.clae.2003.09.005.

Abstract

We studied oxygen supply to the contact lens covered cornea by means of a complex calculation method. We measured lens thicknesses, both centrally and at a 3mm peripheral location, of a range of optical powers of two different spherical silicone hydrogel contact lens designs (manufactured by Ciba Vision and Bausch & Lomb) and one "traditional" hydrogel. Using the measured values of lens thickness and the nominal oxygen permeabilities of these three plastics, we calculated the oxygen tension level in the tear layer posterior to the contact lens and anterior to the cornea and the oxygen flux through these contact lenses, under both open- and closed-eye conditions. We conclude that variable thicknesses of the silicone hydrogel contact lenses does not significantly affect the oxygen tension in the entrapped tear layer, given their high oxygen diffusion coefficients, under open-eye conditions, and probably only minimally under closed-eye conditions as well.

摘要

我们通过一种复杂的计算方法研究了覆盖在角膜上的隐形眼镜的氧气供应情况。我们测量了两种不同球面硅水凝胶隐形眼镜设计(由视康和博士伦生产)以及一种“传统”水凝胶的一系列屈光度镜片在中心和周边3mm位置的厚度。利用所测量的镜片厚度值以及这三种材料的标称透氧率,我们计算了在睁眼和闭眼条件下,隐形眼镜后方泪液层和角膜前方的氧分压水平以及通过这些隐形眼镜的氧通量。我们得出结论,在睁眼条件下,鉴于硅水凝胶隐形眼镜具有较高的氧扩散系数,其厚度变化对被困泪液层中的氧分压没有显著影响,在闭眼条件下可能影响也极小。

相似文献

1
Is contact lens "T" still important?
Cont Lens Anterior Eye. 2004 Mar;27(1):9-14. doi: 10.1016/j.clae.2003.09.005.
2
Predicted tear layer oxygen tensions under two designs of silicone hydrogel toric lenses.
Cont Lens Anterior Eye. 2008 Oct;31(5):228-41; quiz 274-5. doi: 10.1016/j.clae.2008.06.003. Epub 2008 Jul 30.
4
How rigid gas-permeable lenses supply more oxygen to the cornea than silicone hydrogels: a new model.
Eye Contact Lens. 2007 Sep;33(5):216-23. doi: 10.1097/01.icl.0000254523.63767.05.
5
Local oxygen transmissibility of disposable contact lenses.
Cont Lens Anterior Eye. 2003 Dec;26(4):189-96. doi: 10.1016/j.clae.2003.09.001.
6
Corneal oxygen distribution with contact lens wear.
Cornea. 2007 Jul;26(6):654-64. doi: 10.1097/ICO.0b013e31804f5a22.
7
Calculated tear oxygen tension under contact lenses offering resistance in series: piggyback and scleral lenses.
Cont Lens Anterior Eye. 2006 Dec;29(5):231-7. doi: 10.1016/j.clae.2006.09.001. Epub 2006 Oct 24.
8
Changes in UV-visible transmittance of silicone-hydrogel contact lenses induced by wear.
Optom Vis Sci. 2009 Apr;86(4):332-9. doi: 10.1097/OPX.0b013e318198d047.
9
Rigid gas-permeable contact lens base curve radius and transmissibility effects on corneal oxygen uptake.
Optom Vis Sci. 2006 Oct;83(10):740-4. doi: 10.1097/01.opx.0000232806.06677.97.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验