Suppr超能文献

通过电感耦合等离子体质谱法对侧流香烟烟雾中的砷、镉和铅进行测定的撞击收集和浆液采样。

Impaction collection and slurry sampling for the determination of arsenic, cadmium, and lead in sidestream cigarette smoke by inductively coupled plasma-mass spectrometry.

作者信息

Chang Michael J, Walker Kathleen, McDaniel Reta L, Connell Chris T

机构信息

Philip Morris USA, Research Center, 4201 Commerce Road, Richmond, VA 23234, USA.

出版信息

J Environ Monit. 2005 Dec;7(12):1349-54. doi: 10.1039/b509048b. Epub 2005 Oct 21.

Abstract

The slurry sampling technique has been applied for the determination of arsenic, cadmium and lead in sidestream cigarette smoke condensate (SS CSC) by inductively coupled plasma mass spectrometry (ICP-MS). The smoke collection system consists of a "fishtail" chimney in conjunction with an impaction trap and a mixed cellulose ester (MCE) backup filter for the SS CSC collection. The smoke condensates, collected at three different regions of the system (i.e. the inner wall of the chimney, the impaction trap and the MCE filter), were individually prepared and analyzed and showed that about 70 and 20% of Cd and Pb, respectively, were trapped by the impaction trap and the MCE filter with less than 5% trapped by the chimney. In contrast, about 60% of As was trapped by the impactor and a relatively high percentage of As, about 30%, was deposited onto the inner wall of the chimney. The uneven distribution of trace metals at each collection stage strongly suggested that the composition of smoke aerosol and the associated physical form of the analytes may be different. The yields of As, Cd and Pb for the sidestream cigarette smoke of the 1R4F reference cigarette were 29.5 +/- 2.4, 421 +/- 6.6 and 46.4 +/- 0.9 ng cigarette(-1)(n= 3) respectively, when the cigarette was smoked according to the smoking regime: 45 mL puff volume of 2-s puff duration at an interval of 30 s with 50% ventilation holes covered. The analytical results for the slurry sampling technique were also compared with other sample preparation techniques and show good agreement.

摘要

采用浆液进样技术,通过电感耦合等离子体质谱法(ICP-MS)测定了侧流卷烟烟雾冷凝物(SS CSC)中的砷、镉和铅。烟雾收集系统由一个“鱼尾”烟囱、一个冲击捕集器和一个用于收集SS CSC的混合纤维素酯(MCE)备用过滤器组成。在系统的三个不同区域(即烟囱内壁、冲击捕集器和MCE过滤器)收集的烟雾冷凝物分别进行制备和分析,结果表明,约70%的镉和20%的铅分别被冲击捕集器和MCE过滤器捕集,烟囱捕集的不到5%。相比之下,约60%的砷被撞击器捕集,约30%的较高比例的砷沉积在烟囱内壁上。每个收集阶段痕量金属的分布不均强烈表明,烟雾气溶胶的组成和分析物的相关物理形态可能不同。按照以下吸烟模式吸烟时,1R4F参考卷烟侧流卷烟烟雾中砷、镉和铅的产率分别为29.5±2.4、421±6.6和46.4±0.9 ng/支(n = 3):抽吸体积45 mL,抽吸持续时间2 s,间隔30 s,50%通风孔覆盖。还将浆液进样技术的分析结果与其他样品制备技术进行了比较,结果显示吻合良好。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验