Ficarra Vincenzo, Martignoni Guido, Novella Giovanni, Cerruto Maria Angela, Galfano Antonio, Novara Giacomo, Pea Maurizio, Artibani Walter
Department of Urology, University of Verona, Italy.
Eur Urol. 2006 Aug;50(2):266-71. doi: 10.1016/j.eururo.2005.12.057. Epub 2006 Jan 19.
To analyse the length of needle cores sampled as a quality indicator in systematic transperineal prostate biopsy. We assessed the correlation of core length with the other clinical and topographic parameters.
We prospectively evaluated data from 509 consecutive patients who underwent a first set of transrectal ultrasound-guided transperineal prostate biopsy for suspected prostate cancer. Fourteen cores were sampled from each patient. Needle cores were stretched and placed in tissue cassettes between two nylon meshes according to the pre-embedding methods of prostate needle biopsy specimens. For single biopsy core, the measurement of length (in millimetres) and any percentage of cancer in the biopsy specimen were reported.
The mean length of 7,126 analysed cores was 14.14+/-4.35mm. All cores were longer than 10mm. The mean length of needle cores sampled did not correlate with patient age, total prostate-specific antigen value, digital rectal examination, and prostate volume. The whole mean length of the six samples from the peripheral zone of the right lobe was higher than the mean corresponding value of the six samples from the left lobe peripheral zone (p<0.001). The transperineal approach allows a greater sampling of the prostate apex than of the midgland and prostate base (p<0.001).
The length of the needle cores sampled during transperineal prostate biopsy fulfils the parameters of quality required by pathologists for an appropriate evaluation of the biopsy specimen.
分析在系统性经会阴前列腺活检中作为质量指标所采集针芯的长度。我们评估了针芯长度与其他临床和解剖学参数之间的相关性。
我们前瞻性地评估了509例因疑似前列腺癌而接受首次经直肠超声引导下经会阴前列腺活检的连续患者的数据。每位患者采集14根针芯。根据前列腺穿刺活检标本的预包埋方法,将针芯拉伸并置于两个尼龙网之间的组织盒中。对于单个活检针芯,报告其长度(以毫米为单位)以及活检标本中癌组织的任何百分比。
7126根分析针芯的平均长度为14.14±4.35毫米。所有针芯长度均超过10毫米。所采集针芯的平均长度与患者年龄、总前列腺特异性抗原值、直肠指检及前列腺体积均无相关性。右叶外周区六个样本的整体平均长度高于左叶外周区六个样本的相应平均长度(p<0.001)。经会阴途径对前列腺尖部的取材量大于腺体中部和前列腺底部(p<0.001)。
经会阴前列腺活检过程中所采集针芯的长度符合病理学家对活检标本进行适当评估所需的质量参数。