Frich Lars, Hol Per Kristian, Roy Sumit, Mala Tom, Edwin Bjørn, Clausen Ole Petter F, Gladhaug Ivar P
The Interventional Centre, Rikshospitalet University Hospital, 0027, Oslo, Norway.
Eur Radiol. 2006 Sep;16(9):1990-9. doi: 10.1007/s00330-006-0177-6. Epub 2006 Mar 16.
The aim of this study was to examine possible explanatory variables associated with acute and delayed portal vein thrombosis after hepatic radiofrequency (RF) ablation using wet electrodes. Coagulations were created within 1.5 cm of the right portal vein (RPV) branch in 12 pigs with (n = 6) or without (n = 6) Pringle manoeuvre. Sham operations with Pringle manoeuvre were performed in four animals. Rotational portal venography was performed prior to ablation, 10 min after ablation and 4 days after ablation. Vessel diameters and vessel patency was determined from the portal venograms. Distance between the ablation electrode and RPV was measured from 3-dimensional reconstructions of the portal venograms. The portal veins were examined by microscopy. Delayed portal vein thrombosis was found in two of six animals in the Pringle group and three of six animals in the control group 4 days after ablation (P = 1.0, Fisher's exact test). All five occurrences of delayed portal vein thrombosis were found in the six animals with a distance between the ablation electrode and RPV of 5 mm or less (P = 0.030), indicating that the electrode-to-vessel distance may be an independent explanatory factor for delayed portal vein thrombosis after RF ablation with wet electrodes.
本研究的目的是探讨与使用湿电极进行肝脏射频(RF)消融术后急性和延迟性门静脉血栓形成相关的可能解释变量。在12头猪中,在右门静脉(RPV)分支1.5 cm范围内进行凝固,其中6头进行了Pringle手法(n = 6),6头未进行(n = 6)。对4只动物进行了伴有Pringle手法的假手术。在消融前、消融后10分钟和消融后4天进行旋转门静脉造影。从门静脉造影片确定血管直径和血管通畅情况。从门静脉造影片的三维重建测量消融电极与RPV之间的距离。通过显微镜检查门静脉。消融后4天,Pringle组6只动物中有2只出现延迟性门静脉血栓形成,对照组6只动物中有3只出现(P = 1.0,Fisher精确检验)。所有5例延迟性门静脉血栓形成均出现在消融电极与RPV距离为5 mm或更小的6只动物中(P = 0.030),表明电极与血管的距离可能是使用湿电极进行RF消融术后延迟性门静脉血栓形成的一个独立解释因素。