Wiglusz Renata, Sitko Elzbieta, Pecka Irena, Nikel Grazyna
Zakład Toksykologii Srodowiska, Miedzywydziałowy Instytut Medycyny Morskiej i Tropikalnej, Akademia Medyczna w Gdańsku 81-519 Gdynia, ul. Powstania Styczniowego 9 B.
Rocz Panstw Zakl Hig. 2005;56(4):379-86.
An environmental chamber with controlled temperature, relative humidity, and air exchange was used to evaluate emissions of volatile organic compounds (VOC) from three flooring solvent-based adhesives. Gas chromatograph equipped with flame ionization detector was employed to measure VOC emission. The temporal change in concentration of VOC emitted from each adhesive was observed and double-exponential model was compared with a first-order emission decay model in their ability to describe measured emission factors of adhesives. It was demonstrated that the double exponential model better describes emission characteristic for experimental data than first-order model does.