肺转移瘤患者治疗反应的容积评估。计算机系统(CAD)的初步结果及与一维测量的比较。

Volumetric evaluation of therapy response in patients with lung metastases. Preliminary results with a computer system (CAD) and comparison with unidimensional measurements.

作者信息

Fraioli F, Bertoletti L, Napoli A, Calabrese F A, Masciangelo R, Cortesi E, Catalano C, Passariello R

机构信息

Dipartimento di Scienze Radiologiche, Università degli Studi di Roma La Sapienza, Viale Regina Elena 324, I-00161, Roma, Italy.

出版信息

Radiol Med. 2006 Apr;111(3):365-75. doi: 10.1007/s11547-006-0035-2. Epub 2006 Apr 11.

Abstract

PURPOSE

The aim of this study was to assess the efficacy of a Computer-Aided Detection (CAD) system in the identification of lung metastases and to compare the volumetric CAD measurements with unidimensional observer measurements in the evaluation of treatment response in oncology patients.

MATERIALS AND METHODS

Two observers (A and B) evaluated nine patients undergoing lung computed tomography (CT) just before and immediately after treatment with chemotherapy. Multislice CT scans were performed before and after the injection of contrast material with a high-resolution protocol (collimation 4x1 mm, 100 mAs, 120 kV). Response Evaluation Criteria in Solid Tumours (RECIST) criteria were used to consider the disease as stable, increased or decreased. Subsequently, target lesions (most significant lesions identified before and after chemotherapy) were evaluated with a computerised system (CAD) to establish volumetric measurements. Observers' unidimensional measurements and CAD volumetric measurements were analysed for comparison.

RESULTS

Twenty-four nodules (diameter: 5-18 mm in the first study and 4-20 mm in the follow-up study) were included. Observers agreed in the assessment of therapy response in 21 nodules: eight were considered to have increased in size, and 13 were judged stable. Observer and CAD measurements disagreed in three nodules: two were considered stable by radiologists and increased by CAD; one was considered increased by radiologists and stable by CAD.As regards patient response, radiologists disagreed in two cases. CAD and observers did not agree in one case.

CONCLUSIONS

Our preliminary data suggest that volumetric measurements can modify the diagnostic and therapeutic evaluation of oncology patients under chemotherapy.CAD volumetric measurements allow an easy and objective evaluation, reducing interobserver variability in the evaluation of chemotherapy response.

摘要

目的

本研究旨在评估计算机辅助检测(CAD)系统在识别肺转移瘤方面的疗效,并在评估肿瘤患者的治疗反应时,将CAD的体积测量结果与观察者的一维测量结果进行比较。

材料与方法

两名观察者(A和B)在9例接受化疗的患者治疗前及治疗后立即对其进行肺部计算机断层扫描(CT)评估。在注射造影剂前后采用高分辨率方案(准直4×1mm,100mAs,120kV)进行多层CT扫描。实体瘤疗效评价标准(RECIST)用于判断疾病为稳定、进展或缓解。随后,使用计算机系统(CAD)对靶病灶(化疗前后确定的最显著病灶)进行评估以确定体积测量值。分析观察者的一维测量结果和CAD体积测量结果以进行比较。

结果

共纳入24个结节(首次研究中直径为5 - 18mm,随访研究中直径为4 - 20mm)。观察者对21个结节的治疗反应评估意见一致:8个结节被认为增大,13个结节被判定为稳定。观察者和CAD测量结果在3个结节上存在分歧:2个结节放射科医生认为稳定而CAD认为增大;1个结节放射科医生认为增大而CAD认为稳定。关于患者反应,放射科医生在2例中意见不一致。CAD和观察者在1例中意见不一致。

结论

我们的初步数据表明,体积测量可改变对接受化疗的肿瘤患者的诊断和治疗评估。CAD体积测量可实现简便、客观的评估,减少化疗反应评估中的观察者间差异。