INTRODUCTION

Mixing studies are part of the laboratory diagnosis of lupus anticoagulants (LA). They are used to determine the evidence of an inhibitor by demonstrating persistence of an abnormal clotting time by mixing patient plasma with normal plasma. Since there is no standardised interpretation of results of mixing studies, percent correction formulas are proposed. The sensitivity of mixing studies strongly depends on the interpretation of the results.

MATERIALS AND METHODS

A retrospective analysis was performed on 361 samples, 75 LA-positive and 286 LA-negative samples. For all the LA-positive samples and for 181/286 LA-negative samples mixing tests on one or more screening tests were performed. A percent correction formula and the Rosner index were calculated for all mixing tests on aPTT and dPT.

RESULTS

The <70% correction formula for the mixing tests on aPTT showed the highest sensitivity (95%). The Rosner index had a sensitivity (93%) comparable with the <70% correction formula. dPT is shown to be less sensitive in the detection for LA and, even when the screening test is prolonged, interpretation of the mixing test by the percent correction formula misclassifies many samples. Rosner index in the interpretation of mixing tests for dPT is more sensitive than the percent correction formula, 49% and 57%, respectively.

CONCLUSIONS

This study demonstrates that the Rosner index and the percent correction formulas for interpretation of mixing studies are complementary and can help to reduce misclassification of LA-positive or LA-negative samples.

摘要

引言

混合试验是狼疮抗凝物(LA)实验室诊断的一部分。通过将患者血浆与正常血浆混合,观察异常凝血时间是否持续存在,以确定是否存在抑制剂。由于混合试验结果尚无标准化的解读方法,因此提出了百分比校正公式。混合试验的敏感性很大程度上取决于结果的解读。

材料与方法

对361份样本进行回顾性分析,其中75份LA阳性样本和286份LA阴性样本。对所有LA阳性样本以及286份LA阴性样本中的181份进行了一项或多项筛查试验的混合试验。计算了所有活化部分凝血活酶时间(aPTT)和稀释凝血酶原时间(dPT)混合试验的百分比校正公式和罗斯纳指数。

结果

aPTT混合试验的<70%校正公式显示出最高的敏感性(95%)。罗斯纳指数与<70%校正公式的敏感性相当(93%)。dPT在检测LA方面敏感性较低,即使筛查试验延长,用百分比校正公式解读混合试验也会使许多样本分类错误。dPT混合试验解读中罗斯纳指数比百分比校正公式更敏感,分别为49%和57%。

结论

本研究表明,罗斯纳指数和混合试验解读的百分比校正公式是互补的,有助于减少LA阳性或阴性样本的分类错误。