Suppr超能文献

The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery.

作者信息

Elahi Maqsood, Usmaan Khalid

机构信息

Department of Cardiothoracic Surgery, Punjab Institute of Cardiology, Jail Road, Lahore, Pakistan.

出版信息

J Interv Card Electrophysiol. 2006 Mar;15(2):113-8. doi: 10.1007/s10840-006-7750-4.

Abstract

BACKGROUND

Long-standing aortic stenosis (AS) causes significant progressive left ventricular dysfunction and may result in subendocardial ischaemia and conduction disorders. Though stentless bioprosthesis show better haemodynamic profiles compared with stented, yet debate exists about the differential effects of valve substitutes on the incidence of permanent pacemaker (PPM) implantation following aortic valve replacement (AVR).

METHODS

510 consecutive patients aged 65-77 years with predominant AS accepted for isolated non-emergent AVR (360 received stented and 150 stentless) were studied over three years period. A stepwise logistic regression analysis was used and statistical significance was accepted at P < 0.05.

RESULTS

Mean age +/- standard deviation for the stented group was 70.43 +/- 7.2 and the stentless was 61.7 +/- 12.3. Perioperative (30-day) mortality was 1% (5 of the 510 patients). Smaller aortic prosthesis size was identified as a significant predictors of hospital mortality [univariate and multivariate analysis (P < 0.05)]. Risk factors identified for PPM by univariate analysis were: preoperative: age, left atrial enlargement (LAE), MI, left bundle branch block (LBBB), poor ejection fraction < 35% (P < 0.05), postoperative; bypass time > 100 min with x-clamp time > 70 min, concomitant aortic surgery and prosthetic valve size < or = 21 mm (P < 0.05). Multivariate analysis identified the preoperative MI (P = 0.003), poor ejection fraction < 35% (P = 0.007), LAE, (P = 0.001) and LBBB (P = 0.002), the perioperative variables; bypass time > 100 min with x-clamp time > 70 min (P < 0.001) and prosthetic valve size < or = 21 mm (P = 0.003). Test of interaction analysis identified valve type as an important predictor of PPM (P = 0.01).

CONCLUSIONS

The results demonstrated that where stentless valves required longer bypass and cross clamp times, more stented valves were small (< 21 mm, P < 0.05). In précis, this suggests that prevalence of PPM seems to be dependent on the size and type of bioprosthesis used in patients undergoing isolated AVR and this incidence of PPM is twice in stentless group (18% vs. 9.1%, P = 0.01).

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验