Suppr超能文献

BACTEC 9240与BacT/Alert血培养系统检测血小板浓缩物中细菌污染的比较。

Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates.

作者信息

Riedel Stefan, Siwek Gregory, Beekmann Susan E, Richter Sandra S, Raife Thomas, Doern Gary V

机构信息

Division of Clinical Microbiology and Transfusion Medicine, Department of Pathology, University of Iowa College of Medicine, Iowa City, IA 52242, USA.

出版信息

J Clin Microbiol. 2006 Jun;44(6):2262-4. doi: 10.1128/JCM.00635-06.

Abstract

The BACTEC 9240 blood culture system with a standard aerobic medium, Plus Aerobic/F, was compared to the BacT/Alert system with a platelet-specific medium, BPA, as a means for detecting bacterial contamination of platelet preparations. One hundred thirteen platelet units seeded with low levels of different bacteria were examined with both systems. In 93 instances, growth was detected first in the BACTEC system; in 12 cases, growth registered first in the BacT/Alert system. Among all comparisons, growth was detected, on average, 1.7 h sooner with the BACTEC system. The differences in length of time to detection were statistically significant.

摘要

将配备标准需氧培养基(Plus Aerobic/F)的BACTEC 9240血培养系统与配备血小板特异性培养基(BPA)的BacT/Alert系统进行比较,以此作为检测血小板制剂细菌污染的一种方法。用这两种系统检测了接种低水平不同细菌的113个血小板单位。在93例中,BACTEC系统首先检测到生长;在12例中,BacT/Alert系统首先记录到生长。在所有比较中,BACTEC系统平均比其他系统早1.7小时检测到生长。检测时间长度的差异具有统计学意义。

相似文献

9
Comparison of three bacterial detection methods under routine conditions.
Vox Sang. 2007 Jan;92(1):15-21. doi: 10.1111/j.1423-0410.2006.00850.x.

引用本文的文献

1
A prospective study on the effect of time-shifted telephone reporting of blood culture microscopy.
Eur J Clin Microbiol Infect Dis. 2019 May;38(5):973-975. doi: 10.1007/s10096-019-03544-9. Epub 2019 Mar 25.
2
Diagnostic methods for platelet bacteria screening: current status and developments.
Transfus Med Hemother. 2014 Feb;41(1):19-27. doi: 10.1159/000357651. Epub 2013 Dec 30.
3
Implementation of Bacterial Detection Methods into Blood Donor Screening - Overview of Different Technologies.
Transfus Med Hemother. 2011;38(4):259-265. doi: 10.1159/000330305. Epub 2011 Jul 7.
5
Detection of contamination during organ culture of the human cornea.
Graefes Arch Clin Exp Ophthalmol. 2010 Jan;248(1):117-26. doi: 10.1007/s00417-009-1192-5. Epub 2009 Sep 23.
7
Performance evaluation of the VersaTREK blood culture system for quality control testing of platelet units.
J Clin Microbiol. 2009 Mar;47(3):817-8. doi: 10.1128/JCM.02173-08. Epub 2009 Jan 14.

本文引用的文献

2
Bacterial contamination of blood components.
Clin Microbiol Rev. 2005 Jan;18(1):195-204. doi: 10.1128/CMR.18.1.195-204.2005.
3
Impact of clinical practice guidelines on the clinical microbiology laboratory.
J Clin Microbiol. 2004 Apr;42(4):1391-5. doi: 10.1128/JCM.42.4.1391-1395.2004.
7
Transfusion-transmitted bacterial infection in the United States, 1998 through 2000.
Transfusion. 2001 Dec;41(12):1493-9. doi: 10.1046/j.1537-2995.2001.41121493.x.
8
Determinants of transfusion-associated bacterial contamination: results of the French BACTHEM Case-Control Study.
Transfusion. 2001 Jul;41(7):862-72. doi: 10.1046/j.1537-2995.2001.41070862.x.
9
Single-donor platelets reduce the risk of septic platelet transfusion reactions.
Transfusion. 2001 Jul;41(7):857-61. doi: 10.1046/j.1537-2995.2001.41070857.x.