Chung J W, Park J M, Bernhardt R, Pyun J C
Korea Institute for Science and Technology Europe (KIST Europe fGmbH), Stuhlsatzenhausweg 97, 66123 Saarbruecken, Germany.
J Biotechnol. 2006 Nov 10;126(3):325-33. doi: 10.1016/j.jbiotec.2006.05.010. Epub 2006 May 22.
The orientation of antibody was controlled by using NeutrAvidin-protein A complex on the gold surface of SPR biosensor. The surface density of receptor antibody (anti-hIgG) was compared by treatment of receptor antibody to the layer of avidin, NeutrAvidin, protein A, NeutrAvidin-protein A complex and bare gold surface of SPR biosensor. The ligand antibody (hIgG) was injected to each IA layer and the binding ratio of ligand antibody per unit receptor was estimated as a parameter of orientation control. The NeutrAvidin-protein A complex on gold surface of SPR biosensor showed the highest surface density of receptor antibody as well as the binding ratio of ligand antibody per receptor antibody. The NeutrAvidin-protein A complex was also prepared on biotin-labelled SAM, and the binding ratio of ligand per receptor was found to be significantly improved in comparison to the IA layer prepared by chemical coupling of receptor antibody to the SAM layer. The NeutrAvidin-protein A complex which showed the highest efficiency for the binding of ligand antibodies, was applied for the detection of a cancer marker called CEA. By using NeutrAvidin-protein A complex and sandwich assay for signal amplification, sensitivity was improved to be 1.5-fold higher than bare gold surface and the detection of CEA with the detection limit of 30 ng/ml was achieved.
通过在表面等离子体共振(SPR)生物传感器的金表面使用中性抗生物素蛋白-蛋白A复合物来控制抗体的取向。将受体抗体(抗人免疫球蛋白G)处理到抗生物素蛋白层、中性抗生物素蛋白层、蛋白A层、中性抗生物素蛋白-蛋白A复合物层以及SPR生物传感器的裸金表面,比较受体抗体的表面密度。将配体抗体(人免疫球蛋白G)注入到每个免疫分析(IA)层中,并将每单位受体的配体抗体结合率作为取向控制的参数进行估算。SPR生物传感器金表面上的中性抗生物素蛋白-蛋白A复合物显示出最高的受体抗体表面密度以及每个受体抗体的配体抗体结合率。中性抗生物素蛋白-蛋白A复合物也在生物素标记的自组装单分子层(SAM)上制备,并且发现与通过受体抗体与SAM层化学偶联制备的IA层相比,每个受体的配体结合率显著提高。对配体抗体结合效率最高的中性抗生物素蛋白-蛋白A复合物被用于检测一种名为癌胚抗原(CEA)的癌症标志物。通过使用中性抗生物素蛋白-蛋白A复合物和夹心分析法进行信号放大,灵敏度提高到比裸金表面高1.5倍,实现了对CEA的检测,检测限为30 ng/ml。