Werder Robert, Nanz Daniel, Lutz Amelie M, Weishaupt Dominik, McCormack Lucas, Seifert Burkhardt, Marincek Borut, Willmann Jürgen K
Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland.
Eur Radiol. 2007 Feb;17(2):541-51. doi: 10.1007/s00330-006-0384-1. Epub 2006 Sep 1.
The purpose of this study was to evaluate a new three-dimensional gradient-echo (GRE) MR sequence performed with a parallel acquisition technique to shorten breath-hold times (parallel GRE MRI) in the detection of arterial variants and stenosis of the abdominal aorta and its visceral branches. A total of 102 patients underwent dynamic parallel GRE MRI, timed to the arterial phase by a test bolus (mean breath-hold time, 17 s). For both quantitative and qualitative analysis, the abdominal aorta and its visceral branches were divided into 13 arterial segments. In a subanalysis of 55/102 patients, the accuracy of parallel GRE MRI compared to MDCT in the detection arterial variants and stenosis was calculated for two independent readers. Mean SNRs and CNRs were 47.2 and 35.6, respectively. Image quality was rated good or excellent in 1,234/1,326 segments (93%). Hepatic and renal arterial variants were identified with an accuracy of 93 and 95%, respectively (reader 1) and 98 and 100%, respectively (reader 2). Both readers detected arterial stenosis with an accuracy of 98%. Interobserver agreement was good to excellent for the detection of hepatic (kappa=0.69) and renal (kappa=0.92) variants and for the diagnosis of stenosis (kappa=0.96). Dynamic three-dimensional parallel GRE MRI is feasible and allows a reliable and accurate diagnosis of arterial variants and stenosis of the abdominal aorta and its visceral branches in a short breath-hold-time.
本研究的目的是评估一种新的三维梯度回波(GRE)磁共振序列,该序列采用并行采集技术以缩短屏气时间(并行GRE磁共振成像),用于检测腹主动脉及其内脏分支的动脉变异和狭窄。共有102例患者接受了动态并行GRE磁共振成像检查,通过团注试验将其定时至动脉期(平均屏气时间为17秒)。为了进行定量和定性分析,将腹主动脉及其内脏分支分为13个动脉节段。在对102例患者中的55例进行的亚分析中,计算了两位独立阅片者在检测动脉变异和狭窄方面并行GRE磁共振成像相对于多层螺旋CT(MDCT)的准确性。平均信噪比(SNR)和对比噪声比(CNR)分别为47.2和35.6。在1326个节段中的1234个节段(93%)图像质量被评为良好或优秀。肝动脉和肾动脉变异的识别准确率分别为93%和95%(阅片者1)以及98%和100%(阅片者2)。两位阅片者检测动脉狭窄的准确率均为98%。对于肝动脉(kappa=0.69)和肾动脉(kappa=0.92)变异的检测以及狭窄的诊断,观察者间一致性良好至优秀(kappa=0.96)。动态三维并行GRE磁共振成像是可行的,并且能够在短屏气时间内对腹主动脉及其内脏分支的动脉变异和狭窄进行可靠且准确的诊断。