Svensson Elisabeth, Häger-Ross Charlotte
Department of Community Medicine and Rehabilitation, Section of Physiotherapy, Umeå University, Umeå, Sweden.
Clin Rehabil. 2006 Oct;20(10):896-908. doi: 10.1177/0269215506072184.
To evaluate the reliability of some measurements of hand function in people with Charcot Marie Tooth disease.
Test retest study.
University, hospitals/clinics in northern Sweden.
Twenty people with Charcot Marie Tooth disease.
Measures of (1) dexterity; Box and Block Test and Nine-Hole Peg Test, (2) strength; Grippit instrument (grip and pinch), (3) tactile sensation; Shape Texture Identification Test. Statistics used: intraclass correlation (ICC 2.1), limits of agreement, coefficient of repeatability, coefficient of variation, and linear weighted kappa.
The ICC for the Box and Block Test was very high (0.95). The limits of agreement, coefficient of repeatability (CR) (11.5 blocks/min) and coefficient of variation (CV) (8.4%) were acceptable. There was bias towards a better result on the second occasion. For the Nine-Hole Peg Test, the reliability was good if performance was within 2 min (ICC =0.99, CR = 4.3 s, CV = 3.9%). Grip strength proved to be reliable (ICC = 0.99, CR = 26.7 N, CV = 6.6%), while pinch strength was less reliable. The kappa value of the Shape Texture Identification Test was 0.87, which was considered very good although the test has limitations in terms of how well it can describe patients either performing very well or very poorly.
The tested instruments can all be used to evaluate hand function in people with Charcot Marie Tooth. Certain factors, however, like limited time aspects for the Nine-Hole Peg Test and the number of trials used, should be taken into consideration. Pinch strength evaluation should be interpreted with caution.
评估对夏科-马里-图斯病患者手部功能的某些测量方法的可靠性。
重测研究。
瑞典北部的大学、医院/诊所。
20名夏科-马里-图斯病患者。
(1)灵巧性测量;箱块测试和九孔插板测试,(2)力量;握力计(握力和捏力),(3)触觉;形状质地识别测试。使用的统计方法:组内相关系数(ICC 2.1)、一致性界限、重复性系数、变异系数和线性加权kappa值。
箱块测试的ICC非常高(0.95)。一致性界限、重复性系数(CR)(11.5块/分钟)和变异系数(CV)(8.4%)是可接受的。第二次测量时有偏向更好结果的偏差。对于九孔插板测试,如果测试时间在2分钟内,可靠性良好(ICC = 0.99,CR = 4.3秒,CV = 3.9%)。握力被证明是可靠的(ICC = 0.99,CR = 26.7牛,CV = 6.6%),而捏力的可靠性较差。形状质地识别测试的kappa值为0.87,尽管该测试在描述表现非常好或非常差的患者方面存在局限性,但仍被认为非常好。
所测试的仪器均可用于评估夏科-马里-图斯病患者的手部功能。然而,应考虑某些因素,如九孔插板测试的时间限制和使用的试验次数。捏力评估应谨慎解释。