对5种不同近交系未镇静小鼠的眼压进行无创测定。

Noninvasive determination of intraocular pressure (IOP) in nonsedated mice of 5 different inbred strains.

作者信息

Nissirios Nicholas, Goldblum David, Rohrer Kaspar, Mittag Thomas, Danias John

机构信息

Department of Ophthalmology, Mount Sinai School of Medicine, New York, NY 10029, USA.

出版信息

J Glaucoma. 2007 Jan;16(1):57-61. doi: 10.1097/IJG.0b013e31802b3547.

Abstract

BACKGROUND

Noninvasive intraocular pressure (IOP) measurement in mice is critically important for understanding the pathophysiology of glaucoma. Rebound tonometry is one of the methods that can be used for obtaining such measurements. We evaluated the ability of the rebound tonometer (RT) to determine IOP differences among various mouse strains and whether differences in corneal thickness may affect IOP measurements in these animals.

MATERIALS AND METHODS

Five different commonly used mouse strains (BALB/C, CBA/CAHN, AKR/J, CBA/J, and 129P3/J) were used. IOP was measured in eyes from 12 nonsedated animals (6 male and 6 female) from each strain at 2 to 3 months of age using the RT. IOPs were measured in all animals, on 2 different days between 10 AM and 12 PM. Subsequently, a number of eyes from each strain were cannulated to provide a calibration curve specific for that strain. Tonometer readings for all strains were converted to apparent IOP values using the calibration data obtained from the calibration curve of the respective strain. For comparison purposes, IOP values were also obtained using the C57BL/6 calibration data previously reported. IOP for the 5 strains, male and female animals, and the different occasion of measurement were compared using repeat measures analysis of variance. The central corneal thickness (CCT) of another group of 8 male animals from each of the 5 strains was also measured using an optical low coherence reflectometry (OLCR) pachymeter modified for use with mice. CCT values were correlated to mean IOPs of male animals and to the slopes and intercept of individual strain calibration curves.

RESULTS

Noninvasive IOP measurements confirm that the BALB/C strain has lower and the CBA/CAHN has higher relative IOPs than other mouse strains while the AKR/J, the CBA/J, and the 129P3/J strains have intermediate IOPs. There is a very good correlation of apparent IOP values obtained by RT with previously reported true IOPs obtained by cannulation. There was a small but statistically significant difference in IOP between male and female animals in 2 strains (129P3/J and AKR/J) with female mice having higher relative IOPs. No correlation between CCT and IOP was detected. CCT did not correlate with any of the constants describing the calibration curves in the various strains.

CONCLUSIONS

Noninvasive IOP measurement in mice using the RT can be used to help elucidate IOP phenotype, after prior calibration of the tonometer. CCT has no effect on mouse IOP measurements using the RT.

摘要

背景

小鼠的无创眼压测量对于理解青光眼的病理生理学至关重要。回弹眼压计是可用于获取此类测量值的方法之一。我们评估了回弹眼压计(RT)测定不同小鼠品系之间眼压差异的能力,以及角膜厚度差异是否会影响这些动物的眼压测量。

材料与方法

使用了五种不同的常用小鼠品系(BALB/C、CBA/CAHN、AKR/J、CBA/J和129P3/J)。在2至3月龄时,使用RT对来自每个品系的12只未麻醉动物(6只雄性和6只雌性)的眼睛进行眼压测量。在上午10点至中午12点之间的2个不同日期对所有动物进行眼压测量。随后,对每个品系的一些眼睛进行插管以提供该品系特有的校准曲线。使用从各个品系的校准曲线获得的校准数据,将所有品系的眼压计读数转换为表观眼压值。为了进行比较,还使用先前报道的C57BL/6校准数据获得眼压值。使用重复测量方差分析比较5个品系、雄性和雌性动物以及不同测量时间的眼压。还使用为小鼠使用而改装的光学低相干反射测量(OLCR)角膜厚度仪测量了来自5个品系的另一组8只雄性动物的中央角膜厚度(CCT)。CCT值与雄性动物的平均眼压以及各个品系校准曲线的斜率和截距相关。

结果

无创眼压测量证实,BALB/C品系的相对眼压低于其他小鼠品系,而CBA/CAHN品系的相对眼压高于其他小鼠品系,而AKR/J、CBA/J和129P3/J品系的眼压处于中间水平。RT获得的表观眼压值与先前通过插管获得的真实眼压值具有很好的相关性。在2个品系(129P3/J和AKR/J)中,雄性和雌性动物之间的眼压存在微小但具有统计学意义的差异,雌性小鼠的相对眼压较高。未检测到CCT与眼压之间的相关性。CCT与描述各个品系校准曲线的任何常数均无相关性。

结论

在眼压计预先校准后,使用RT对小鼠进行无创眼压测量可用于帮助阐明眼压表型。CCT对使用RT测量小鼠眼压没有影响。