Accelographic train-of-four at near-threshold currents.

作者信息

Silverman D G, Connelly N R, O'Connor T Z, Garcia R, Brull S J

机构信息

Department of Anesthesiology, Yale University School of Medicine, Yale-New Haven Hospital, Connecticut 06510.

出版信息

Anesthesiology. 1992 Jan;76(1):34-8. doi: 10.1097/00000542-199201000-00005.

DOI:10.1097/00000542-199201000-00005
PMID:1729934
Abstract

The authors evaluated train-of-four (TOF) fade, as quantified by accelography, in response to neurostimulation at currents ranging from 10 to 60 mA. This was done to determine the range of currents over which measurements of fade remain consistent. In 31 patients (ASA Physical Status 1,2, and 3), anesthesia was induced with fentanyl, midazolam, and thiopental and was maintained with isoflurane and 66% nitrous oxide in oxygen. Surface stimulating electrodes were placed over the ulnar nerve, and an acceleration transducer was placed on the thumb. Succinylcholine was administered to facilitate tracheal intubation; after neuromuscular recovery, a bolus of vecuronium (0.01-0.05 mg.kg-1) and an infusion (0.25-1.5 micrograms.kg-1.min-1) were administered. After documentation of a stable TOF ratio, accelographic TOF responses were quantified in response to 200-microseconds stimulation at 10, 15, 20, 30, 40, 50, and 60 mA, in random order. A total of 95 data sets were collected at different depths of blockade. The TOF ratios maintained intercurrent consistency (P = not significant by nonparametric repeated measures analysis of variance), except at currents near the fourth-twitch (T4) threshold current. This inconsistency was eliminated by testing at greater than or equal to 10 mA above threshold. TOF ratios obtained at 10 mA above T4 threshold correlated highly with those at 60 mA (Spearman r value = 0.94). The authors conclude that the TOF ratio is consistent over a wide range of stimulating currents and that testing with submaximal currents can be performed reliably at greater than or equal to 10 mA above the T4 threshold.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

相似文献

1
Accelographic train-of-four at near-threshold currents.
Anesthesiology. 1992 Jan;76(1):34-8. doi: 10.1097/00000542-199201000-00005.
2
Assessment of double-burst monitoring at 10 mA above threshold current.
Can J Anaesth. 1993 Jun;40(6):502-6. doi: 10.1007/BF03009730.
3
The accuracy of train-of-four monitoring at varying stimulating currents.
Anesthesiology. 1992 Feb;76(2):199-203. doi: 10.1097/00000542-199202000-00007.
4
Optimal stimulating current for train-of-four stimulation in conscious subjects.清醒受试者中四个成串刺激的最佳刺激电流
Can J Anaesth. 1995 Nov;42(11):992-5. doi: 10.1007/BF03011071.
5
Relationship between stimulating current and accelographic train-of-four response at the great toe.
Anaesthesia. 1999 Nov;54(11):1099-103. doi: 10.1046/j.1365-2044.1999.01072.x.
6
Correlation of train-of-four and double burst stimulation ratios at varying amperages.
Anesth Analg. 1990 Nov;71(5):489-92. doi: 10.1213/00000539-199011000-00006.
7
Real time versus slow-motion train-of-four monitoring: a theory to explain the inaccuracy of visual assessment.实时与慢动作四个成串刺激监测:一种解释视觉评估不准确的理论
Anesth Analg. 1995 Mar;80(3):548-51. doi: 10.1097/00000539-199503000-00020.
8
A comparison of dynamic and isometric force sensors for train-of-four measurement using submaximal stimulation current.
J Clin Monit. 1995 Jan;11(1):18-22. doi: 10.1007/BF01627415.
9
Visual assessment of train-of-four and double burst-induced fade at submaximal stimulating currents.
Anesth Analg. 1991 Nov;73(5):627-32. doi: 10.1213/00000539-199111000-00020.
10
Stimulation with submaximal current for train-of-four monitoring.用次最大电流刺激进行四个成串刺激监测。
Anesthesiology. 1990 Apr;72(4):629-32. doi: 10.1097/00000542-199004000-00009.

引用本文的文献

1
Subparalyzing Doses of Rocuronium Reduce Muscular Endurance without Detectable Effect on Single Twitch Height in Awake Subjects.低于麻痹剂量的罗库溴铵可降低清醒受试者的肌肉耐力,但对单收缩高度无明显影响。
Anesthesiol Res Pract. 2019 May 2;2019:2897406. doi: 10.1155/2019/2897406. eCollection 2019.
2
Visual evaluation of TOF and DBS fade using a rubber band.使用橡皮筋对TOF和DBS消退进行视觉评估。
Can J Anaesth. 1996 Mar;43(3):316-7. doi: 10.1007/BF03011753.
3
Why all muscles are not alike.
Can J Anaesth. 1996 Jun;43(6):549-33. doi: 10.1007/BF03011764.
4
Recovery of post-tetanic and train-of-four responses at the first dorsal interosseous and adductor pollicis muscles in patients receiving vecuronium.接受维库溴铵治疗的患者第一背侧骨间肌和拇收肌的强直后和四个成串刺激反应的恢复情况。
Can J Anaesth. 1996 Apr;43(4):362-7. doi: 10.1007/BF03011715.
5
Post-tetanic burst count: a stimulating pattern for profound neuromuscular blockade.强直后爆发计数:一种实现深度神经肌肉阻滞的刺激模式。
Can J Anaesth. 1995 Dec;42(12):1096-100. doi: 10.1007/BF03015095.
6
Optimal stimulating current for train-of-four stimulation in conscious subjects.清醒受试者中四个成串刺激的最佳刺激电流
Can J Anaesth. 1995 Nov;42(11):992-5. doi: 10.1007/BF03011071.
7
Assessment of double-burst monitoring at 10 mA above threshold current.
Can J Anaesth. 1993 Jun;40(6):502-6. doi: 10.1007/BF03009730.
8
Monitoring of neuromuscular function in the clinical setting.临床环境中神经肌肉功能的监测。
Yale J Biol Med. 1993 Sep-Oct;66(5):473-89.