Suppr超能文献

印度农村人口白内障囊外摘除术后后囊膜混浊:可折叠丙烯酸酯与聚甲基丙烯酸甲酯人工晶状体的随机临床试验

Posterior capsule opacification after extra capsular cataract extraction in Indian rural population: foldable acrylic vs poly (methyl-methacrylate) intraocular lenses a randomized clinical trial.

作者信息

Shah A R, Praveen M R, Vasavada A R

机构信息

Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India.

出版信息

Eye (Lond). 2008 Jul;22(7):889-94. doi: 10.1038/sj.eye.6702747. Epub 2007 Feb 23.

Abstract

PURPOSE

To compare the performance of single-piece acrylic vspoly (methylmethacrylate) intraocular lenses (IOL) on the development of posterior capsule opacification (PCO) after conventional extra capsular cataract extraction (ECCE).

MATERIALS AND METHODS

One hundred and eighty-two eyes of 91 patients with bilateral senile cataract undergoing ECCE were prospectively randomized to receive a single-piece Alcon AcrySof SA60AT IOL or a single-piece EPOCH polymethylmethacrylate IOL in the first eye to have surgery. At 1, 6 and 12 months post-operative follow-up, digital retro illumination images of the posterior capsule were taken for PCO assessment semi-objectively using PCO (POCO automated analysis software) system. Relationship of anterior capsule contact (total off and partial cover) on optic for PCO was analyzed.

RESULTS

The AcrySof IOL was associated with less PCO than EPOCH lens at 6 months (10.01+/-8.75% vs 32.26+/-27.44%; P<0.001) and 1-year (11.65+/-10.55% vs 38.38+/-29.62%; P<0.001) follow-up. The EPOCH IOL showed a remarkably significant difference on development of PCO with anterior capsule overlap on IOL optic (total off and part on) 1 year (P<0.039), whereas no such difference was observed with the AcrySof IOL (P=0.197).

CONCLUSION

The AcrySof IOL led to significantly less PCO than the EPOCH IOL post-operatively after extracapsular cataract extraction.

摘要

目的

比较单片丙烯酸酯与聚甲基丙烯酸甲酯人工晶状体(IOL)在常规囊外白内障摘除术(ECCE)后后囊膜混浊(PCO)发生情况方面的性能。

材料与方法

91例双侧老年性白内障患者的182只眼睛接受ECCE,前瞻性随机分为在第一只接受手术的眼中植入单片爱尔康AcrySof SA60AT IOL或单片EPOCH聚甲基丙烯酸甲酯IOL。在术后1、6和12个月随访时,使用PCO(POCO自动分析软件)系统对后囊膜进行数字后照照明成像,以半客观方式评估PCO。分析了人工晶状体光学部前囊膜接触(完全脱离和部分覆盖)与PCO的关系。

结果

在6个月(10.01±8.75%对32.26±27.44%;P<0.001)和1年(11.65±10.55%对38.38±29.62%;P<0.001)随访时,AcrySof IOL的PCO发生率低于EPOCH晶状体。EPOCH IOL在人工晶状体光学部前囊膜重叠(完全脱离和部分接触)1年时PCO的发生有显著差异(P<0.039),而AcrySof IOL未观察到此类差异(P=0.197)。

结论

囊外白内障摘除术后,AcrySof IOL导致的PCO明显少于EPOCH IOL。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验