Arcovedo R, Barrera H, Reyes H S
Department of General Surgery, Coast Surgical Group, 855 Third Avenue, Suite 3340, Chula Vista, CA, 91911, USA.
Surg Endosc. 2007 Oct;21(10):1764-7. doi: 10.1007/s00464-007-9239-3. Epub 2007 Mar 13.
Laparoscopic appendectomy (LA) has become very popular. One criticism of this approach is the high cost of the disposable equipment such as the linear stapler. An alternative would be suture ligation of the appendiceal base. To prove the safety of the Gea extracorporeal sliding knot (GESK) for closure of the stump after LA, a retrospective study was conducted.
For this study, 63 LA procedures performed by one surgeon using the Gea knot (group A) were reviewed and compared with 63 LA procedures performed by two other surgeons (group B) using the linear stapler. The GESK is created with 0-prolene in the manner already described. The main variable was the presence or absence of blowout, leak, or fistula from the appendiceal stump. The secondary variables were abdominal abscess, wound infection, and need for readmission or reoperation. The results were analyzed using the appropriate statistical methods.
Both groups were similar in terms of age, gender, and pathologic diagnosis. No patient in group A or B experienced a colonic fistula, stump blowout, or leak. In group A, one patient experienced interloop abscesses. There were two wound infections. In group B, one patient experienced a wound infection, and another patient had a wound dehiscence of the umbilical port, which required reoperation. No statistical differences were noted between the two groups.
There are surgeons who routinely use sutures to secure the stump of the appendectomy. This study aimed to demonstrate that the GESK is as secure as the stapler for closure of the appendiceal stump. The GESK could be passed through a 5-mm trocar, potentially avoiding complications of a larger trocar site. The GESK seems to be an economic and safe alternative to the stapler.
腹腔镜阑尾切除术(LA)已变得非常普遍。对这种方法的一种批评是一次性设备(如线性吻合器)成本高昂。另一种选择是阑尾根部的缝合结扎。为了证明Gea体外滑动结(GESK)用于LA术后残端闭合的安全性,进行了一项回顾性研究。
在本研究中,回顾了由一名外科医生使用Gea结进行的63例LA手术(A组),并与另外两名外科医生使用线性吻合器进行的63例LA手术(B组)进行比较。GESK采用0号普理灵以已描述的方式制作。主要变量是阑尾残端是否存在穿孔、渗漏或瘘管。次要变量是腹腔脓肿、伤口感染以及再次入院或再次手术的必要性。使用适当的统计方法分析结果。
两组在年龄、性别和病理诊断方面相似。A组或B组均无患者发生结肠瘘、残端穿孔或渗漏。A组有1例患者发生肠袢间脓肿,有2例伤口感染。B组有1例患者发生伤口感染,另1例患者脐部切口裂开,需要再次手术。两组之间未发现统计学差异。
有外科医生常规使用缝线固定阑尾切除术的残端。本研究旨在证明GESK在闭合阑尾残端方面与吻合器一样安全。GESK可通过5毫米套管针置入,有可能避免较大套管针穿刺部位的并发症。GESK似乎是吻合器的一种经济且安全的替代方法。