Suppr超能文献

硅水凝胶和低透氧性水凝胶延长佩戴时间的隐形眼镜引发角膜炎症事件的风险:一项荟萃分析。

Risk of corneal inflammatory events with silicone hydrogel and low dk hydrogel extended contact lens wear: a meta-analysis.

作者信息

Szczotka-Flynn Loretta, Diaz Mireya

机构信息

Department of Ophthalmology, Case Western Reserve University, Cleveland, Ohio 44106, USA.

出版信息

Optom Vis Sci. 2007 Apr;84(4):247-56. doi: 10.1097/OPX.0b013e3180421c47.

Abstract

PURPOSE

High Dk silicone hydrogel (SH) lenses have been shown to significantly decrease the risk of hypoxic complications compared to traditional low Dk hydrogels. However, the risks of inflammatory complications with SH compared to low Dk lenses are not as clear. A meta-analysis was performed to combine the relevant literature to evaluate the risks of corneal inflammatory events in users of SH and low Dk hydrogel extended wear lenses.

METHODS

A systematic search was conducted using online databases, unpublished meeting abstracts, and retrieval of other cited references presented or published between 1990 and February 2006. Each study was evaluated for quality in terms of the research question, and these quality assessments were used to determine which studies should be used in subgroup analyses. A generalized linear mixed model framework with an underlying Poisson distribution for the occurrence of events was employed to combine information from the included studies.

RESULTS

Twenty-three studies published or presented on either or both arms by February 2006 were selected for analysis. A total of 9,336 subjects and 18,537 eyes comprised the entire sample. Seven studies were published in the 1990s. Eighteen studies (78%) were prospective, and 11 (48%) used randomization. The follow-up ranged from 4 to 36 months, with a median of 12 months. The rates of infiltrates for low Dk hydrogels and SH lenses were 7.7 (2.2, 26.7) and 14.4 (4.3, 48.2) per 100 eye-years, respectively. In the subset of five best quality studies, the unadjusted risk ratio for corneal inflammatory events for SH lenses compared to low Dk lenses was 2.18 (p < 0.005). Across studies, adjusted risk ratios ranged from 2.18 to 2.23 (p < 0.05), with strong confounding between material and length of wear.

CONCLUSIONS

Based on published or presented studies between 1991 and 2006, there is approximately a twofold higher risk for corneal inflammatory events in users of SH lenses when typically worn for up to 30 days extended wear when compared with low Dk extended wear lenses when typically worn for 7 days extended wear. The increased risk cannot be definitively linked to SH lens materials because the effect of material on outcome is confounded by length of wear.

摘要

目的

与传统的低Dk水凝胶相比,高Dk硅水凝胶(SH)镜片已被证明可显著降低缺氧并发症的风险。然而,与低Dk镜片相比,SH镜片发生炎症并发症的风险尚不清楚。进行一项荟萃分析,综合相关文献,以评估SH镜片和低Dk水凝胶长戴型镜片使用者发生角膜炎症事件的风险。

方法

使用在线数据库、未发表的会议摘要以及检索1990年至2006年2月期间发表或公布的其他引用参考文献进行系统检索。根据研究问题对每项研究的质量进行评估,这些质量评估用于确定哪些研究应纳入亚组分析。采用具有潜在泊松分布的广义线性混合模型框架来合并纳入研究的信息。

结果

选择了2006年2月前发表或公布的关于单臂或双臂的23项研究进行分析。整个样本共有9336名受试者和18537只眼睛。7项研究发表于20世纪90年代。18项研究(78%)为前瞻性研究,11项研究(48%)采用了随机分组。随访时间为4至36个月,中位数为12个月。低Dk水凝胶镜片和SH镜片的浸润发生率分别为每100眼年7.7(2.2,26.7)和14.4(4.3,48.2)。在五项质量最佳的研究子集中,SH镜片与低Dk镜片相比,角膜炎症事件的未调整风险比为2.18(p<0.005)。在所有研究中,调整后的风险比在2.18至2.23之间(p<0.05),材料与佩戴时长之间存在强烈的混杂因素。

结论

基于1991年至2006年发表或公布的研究,与低Dk长戴型镜片(通常佩戴7天的长戴时间)相比,SH镜片使用者(通常佩戴长达30天的长戴时间)发生角膜炎症事件的风险大约高出两倍。风险增加不能明确归因于SH镜片材料,因为材料对结果的影响因佩戴时长而混淆。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验