Abstract

Background With the development of cord blood banking, solutions have to be found to solve the storage space problem, by reducing the volume of cord blood units (CBU). Methods We compared total nucleated cell (TNC) and CD34(+) cell counts before and after processing with three different CBU volume reduction methods used consecutively in our bank: a manual method based on hydroxyethyl starch sedimentation (HES) (n=447), a top-and-bottom (TB) semi-automated method (n=181) using Optipress II, and the Sepax automated method (n=213). Statistical analysis was done using t-tests, linear regression and Spearman correlation coefficients. Adjusted variables included TNC, CD34(+) cell counts, CD34(+) cell percentage and CB volume before processing. Results TNC recovery was higher with Sepax (80.3+/-7.7%) than with HES (76.8+/-9.1%) and TB (60.7+/-13.5%) (P<0.0001, both). It was higher with HES than with TB (P<0.0001). CD34(+) cell recovery was higher with Sepax (86+/-11.6%) than with HES (81.5+/-12.5%) and TB (82.0+/-17.7%) (P<0.008 and <0.0001, respectively) and results with HES and TB were not significantly different (P=0.7). Interestingly, with Sepax, TNC and CD34(+) cell recoveries were not correlated with pre-processing values (P=0.8 and 0.4, respectively). Discussion In conclusion, the Sepax volume reduction method allows higher TNC and CD34(+) cell recoveries.

摘要

背景 随着脐带血库的发展,必须找到解决方案以通过减少脐带血单位(CBU)的体积来解决存储空间问题。方法 我们比较了在我们的血库中连续使用的三种不同的CBU体积减少方法处理前后的总核细胞(TNC)和CD34(+)细胞计数:一种基于羟乙基淀粉沉降(HES)的手动方法(n = 447),一种使用Optipress II的上下(TB)半自动方法(n = 181),以及Sepax自动方法(n = 213)。使用t检验、线性回归和Spearman相关系数进行统计分析。调整变量包括处理前的TNC、CD34(+)细胞计数、CD34(+)细胞百分比和CB体积。结果 Sepax方法的TNC回收率(80.3±7.7%)高于HES方法(76.8±9.1%)和TB方法(60.7±13.5%)(两者P均<0.0001)。HES方法的回收率高于TB方法(P<0.0001)。Sepax方法的CD34(+)细胞回收率(86±11.6%)高于HES方法(81.5±12.5%)和TB方法(82.0±17.7%)(分别为P<0.008和<0.0001),HES方法和TB方法的结果无显著差异(P = 0.7)。有趣的是,使用Sepax方法时,TNC和CD34(+)细胞回收率与处理前的值无关(分别为P = 0.8和0.4)。讨论 总之,Sepax体积减少方法可实现更高的TNC和CD34(+)细胞回收率。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验