Suppr超能文献

心内超声换能器的辐射力成像挑战与实施

Challenges and implementation of radiation-force imaging with an intracardiac ultrasound transducer.

作者信息

Hsu Stephen J, Fahey Brian J, Dumont Douglas M, Wolf Patrick D, Trahey Gregg E

机构信息

Duke University, Durham, NC, USA.

出版信息

IEEE Trans Ultrason Ferroelectr Freq Control. 2007 May;54(5):996-1009. doi: 10.1109/tuffc.2007.345.

Abstract

Intracardiac echocardiography (ICE) has been demonstrated to be an effective imaging modality for the guidance of several cardiac procedures, including radiofrequency ablation (RFA). However, assessing lesion size during the ablation with conventional ultrasound has been limited, as the associated changes within the B-mode images often are subtle. Acoustic radiation force impulse (ARFI) imaging is a promising modality to monitor RFAs as it is capable of visualizing variations in local stiffnesses within the myocardium. We demonstrate ARFI imaging with an intracardiac probe that creates higher quality images of the developing lesion. We evaluated the performance of an ICE probe with ARFI imaging in monitoring RFAs. The intracardiac probe was used to create high contrast, high resolution ARFI images of a tissue-mimicking phantom containing stiffer spherical inclusions. The probe also was used to examine an excised segment of an ovine right ventricle with a RFA-created surface lesion. Although the lesion was not visible in conventional B-mode images, the ARFI images were able to show the boundaries between the lesion and the surrounding tissue. ARFI imaging with an intracardiac probe then was used to monitor cardiac ablations in vivo. RFAs were performed within the right atrium of an ovine heart, and B-mode and ARFI imaging with the intracardiac probe was used to monitor the developing lesions. Although there was little indication of a developing lesion within the B-mode images, the corresponding ARFI images displayed regions around the ablation site that displaced less.

摘要

心腔内超声心动图(ICE)已被证明是指导包括射频消融(RFA)在内的多种心脏手术的有效成像方式。然而,在消融过程中使用传统超声评估病变大小存在局限性,因为B模式图像中的相关变化通常很细微。声辐射力脉冲(ARFI)成像作为一种能够可视化心肌内局部硬度变化的技术,是监测RFA的一种有前景的方式。我们展示了使用心腔内探头进行ARFI成像,该探头能生成发育中病变的更高质量图像。我们评估了带有ARFI成像功能的心腔内探头在监测RFA方面的性能。心腔内探头用于创建含有较硬球形内含物的组织模拟体模的高对比度、高分辨率ARFI图像。该探头还用于检查带有RFA造成的表面病变的绵羊右心室切除段。尽管在传统B模式图像中病变不可见,但ARFI图像能够显示病变与周围组织之间的边界。然后,使用带有心腔内探头的ARFI成像来监测体内心脏消融。在绵羊心脏的右心房内进行RFA,并使用心腔内探头进行B模式和ARFI成像来监测发育中的病变。尽管在B模式图像中几乎没有病变发展的迹象,但相应的ARFI图像显示消融部位周围的区域位移较小。

相似文献

9

引用本文的文献

2
Cardiac Lesion Mapping In Vivo Using Intracardiac Myocardial Elastography.利用心内心肌弹性成像技术进行活体心脏损伤定位。
IEEE Trans Ultrason Ferroelectr Freq Control. 2018 Jan;65(1):14-20. doi: 10.1109/TUFFC.2017.2768301.
3
Recent technological advancements in cardiac ultrasound imaging.心脏超声成像的最新技术进展。
Ultrasonics. 2018 Mar;84:329-340. doi: 10.1016/j.ultras.2017.11.013. Epub 2017 Nov 23.
4
5
Robust Tracking of Small Displacements With a Bayesian Estimator.使用贝叶斯估计器对小位移进行稳健跟踪。
IEEE Trans Ultrason Ferroelectr Freq Control. 2016 Jan;63(1):20-34. doi: 10.1109/TUFFC.2015.2495111. Epub 2015 Oct 27.

本文引用的文献

1
A parallel tracking method for acoustic radiation force impulse imaging.一种用于声辐射力脉冲成像的并行跟踪方法。
IEEE Trans Ultrason Ferroelectr Freq Control. 2007 Feb;54(2):301-12. doi: 10.1109/tuffc.2007.244.
3
Rapid tracking of small displacements with ultrasound.用超声快速追踪小位移。
IEEE Trans Ultrason Ferroelectr Freq Control. 2006 Jun;53(6):1103-17. doi: 10.1109/tuffc.2006.1642509.
5
A finite-element method model of soft tissue response to impulsive acoustic radiation force.软组织对脉冲声辐射力响应的有限元方法模型。
IEEE Trans Ultrason Ferroelectr Freq Control. 2005 Oct;52(10):1699-712. doi: 10.1109/tuffc.2005.1561624.