Suppr超能文献

通过纳入粘性阻尼假设指数衰减可改善全关节摆动试验中摩擦系数的预测。

Assuming exponential decay by incorporating viscous damping improves the prediction of the coefficient of friction in pendulum tests of whole articular joints.

作者信息

Crisco J J, Blume J, Teeple E, Fleming B C, Jay G D

机构信息

Bioengineering Laboratory, Department of Orthopaedics, Brown Medicine School/Rhode Island Hospital, Providence, Rhode Island 02903, USA.

出版信息

Proc Inst Mech Eng H. 2007 Apr;221(3):325-33. doi: 10.1243/09544119JEIM248.

Abstract

A pendulum test with a whole articular joint serving as the fulcrum is commonly used to measure the bulk coefficient of friction (COF). In such tests it is universally assumed that energy loss is due to frictional damping only, and accordingly the decay of pendulum amplitude is linear with time. The purpose of this work was to determine whether the measurement of the COF is improved when viscous damping and exponential decay of pendulum amplitude are incorporated into a lumped-parameter model. Various pendulum models with a range of values for COF and for viscous damping were constructed. The resulting decay was fitted with an exponential function (including both frictional and viscous damping) and with a linear decay function (frictional damping only). The values predicted from the fit of each function were then compared to the known values. It was found that the exponential decay function was able to predict the COF values within 2 per cent error. This error increased for models in which the damping coefficient was relatively small and the COF was relatively large. On the other hand, the linear decay function resulted in large errors in the prediction of the COF, even for small values of viscous damping. The exponential decay function including both frictional and constant viscous damping presented herein dramatically increased the accuracy of measuring the COF in a pendulum test of modelled whole articular joints.

摘要

一种以整个关节作为支点的摆锤试验通常用于测量体积摩擦系数(COF)。在这类试验中,人们普遍认为能量损失仅源于摩擦阻尼,因此摆锤振幅的衰减与时间呈线性关系。这项工作的目的是确定当将粘性阻尼和摆锤振幅的指数衰减纳入集总参数模型时,COF的测量是否会得到改善。构建了具有一系列COF值和粘性阻尼值的各种摆锤模型。将得到的衰减分别用指数函数(包括摩擦阻尼和粘性阻尼)和线性衰减函数(仅摩擦阻尼)进行拟合。然后将每个函数拟合预测的值与已知值进行比较。结果发现,指数衰减函数能够在2%的误差范围内预测COF值。对于阻尼系数相对较小且COF相对较大的模型,该误差会增大。另一方面,即使粘性阻尼值很小,线性衰减函数在预测COF时也会产生较大误差。本文提出的包含摩擦阻尼和恒定粘性阻尼的指数衰减函数显著提高了在模拟全关节摆锤试验中测量COF的准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验