通过X射线断层扫描评估骨对钛涂层聚甲基丙烯酸甲酯树脂(PMMA)植入物的反应。

Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography.

作者信息

Shalabi Manal M, Wolke Johannes G C, Cuijpers Vincent M J I, Jansen John A

机构信息

Department of Periodontology and Biomaterials, Dentistry 309, Radboud University Nijmegen Medical Center, PO Box 9101, 6500 HB Nijmegen, The Netherlands.

出版信息

J Mater Sci Mater Med. 2007 Oct;18(10):2033-9. doi: 10.1007/s10856-007-3160-0. Epub 2007 Jun 9.

Abstract

High-resolution three-dimensional data about the bone response to oral implants can be obtained by using microfocus computer tomography. However, a disadvantage is that metallic implants cause streaking artifacts due to scattering of X-rays, which prevents an accurate evaluation of the interfacial bone-to-implant contact. It has been suggested that the use of thin titanium coatings deposited on polymeric implants can offer an alternative option for analyzing bone contact using micro-CT imaging. Consequently, the aim of the current study was to investigate bone behavior to titanium-coated polymethylmethacrylate (PMMA) implants by micro-CT and histological evaluation. For the experiment titanium-coated PMMA implants were used. The implants had a machined threaded appearance and were provided with a 400-500 nm thick titanium coating. The implants were inserted in the right or left tibia of 10 goats. After an implantation period of 12 weeks the implants were retrieved and prepared for micro-computer tomography (microCT), light microscopy, and X-ray microanalysis. The micro-CT showed that the screw-threads and typical implant configuration were well maintained through the installation procedure. Overall, histological responses showed that the titanium-coated implants were well tolerated and caused no atypical tissue response. In addition, the bone was seen in direct contact with the titanium-coated layer. The X-ray microanalysis results confirmed the light microscopical data. In conclusion, the obtained results proof the final use of titanium-coated PMMA implants for evaluation of the bone-implant response using microCT. However, this study also confirms that for a proper analysis of the bone-implant interface the additional use of microscopical techniques is still required.

摘要

通过使用微焦点计算机断层扫描,可以获得有关口腔种植体骨反应的高分辨率三维数据。然而,一个缺点是金属种植体会因X射线散射而产生条纹伪影,这会妨碍对种植体与骨界面接触的准确评估。有人提出,在聚合物种植体上沉积薄钛涂层可为使用微型计算机断层扫描成像分析骨接触提供另一种选择。因此,本研究的目的是通过微型计算机断层扫描和组织学评估来研究骨对钛涂层聚甲基丙烯酸甲酯(PMMA)种植体的反应。实验使用了钛涂层PMMA种植体。这些种植体具有加工后的螺纹外观,并带有400 - 500纳米厚的钛涂层。将种植体植入10只山羊的右胫骨或左胫骨中。植入12周后,取出种植体并准备进行微型计算机断层扫描(microCT)、光学显微镜检查和X射线微分析。微型计算机断层扫描显示,在整个安装过程中,螺纹和典型的种植体结构保持良好。总体而言,组织学反应表明钛涂层种植体耐受性良好,未引起非典型组织反应。此外,可见骨与钛涂层直接接触。X射线微分析结果证实了光学显微镜数据。总之,所获得的结果证明了钛涂层PMMA种植体最终可用于通过微型计算机断层扫描评估骨 - 种植体反应。然而,本研究也证实,为了正确分析骨 - 种植体界面,仍然需要额外使用显微镜技术。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验