门控灌注单光子发射计算机断层扫描成像中的定量分析:雪松西奈医疗中心的方法。

Quantitation in gated perfusion SPECT imaging: the Cedars-Sinai approach.

作者信息

Germano Guido, Kavanagh Paul B, Slomka Piotr J, Van Kriekinge Serge D, Pollard Geoff, Berman Daniel S

机构信息

Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, Calif 90048, USA.

出版信息

J Nucl Cardiol. 2007 Jul;14(4):433-54. doi: 10.1016/j.nuclcard.2007.06.008.

Abstract

Cedars-Sinai's approach to the automation of gated perfusion single photon emission computed tomography (SPECT) imaging is based on the identification of key procedural steps (processing, quantitation, reporting), each of which is then implemented, in completely automated fashion, by use of mathematic algorithms and logical rules combined into expert systems. Our current suite of software applications has been designed to be platform- and operating system-independent, and every algorithm is based on the same 3-dimensional sampling scheme for the myocardium. The widespread acceptance of quantitative software by the nuclear cardiology community (QGS alone is used at over 20,000 locations) has provided the opportunity for extensive validation of quantitative measurements of myocardial perfusion and function, in our opinion, helping to make nuclear cardiology the most accurate and reproducible modality available for the assessment of the human heart.

摘要

雪松西奈医疗中心(Cedars-Sinai)对门控灌注单光子发射计算机断层扫描(SPECT)成像自动化的方法基于关键程序步骤(处理、定量、报告)的识别,然后通过将数学算法和逻辑规则组合到专家系统中,以完全自动化的方式实施每个步骤。我们当前的软件应用套件设计为与平台和操作系统无关,并且每个算法都基于相同的心肌三维采样方案。核心脏病学界对定量软件的广泛接受(仅定量门控心肌灌注分析软件(QGS)就在超过20000个地点使用)为心肌灌注和功能定量测量的广泛验证提供了机会,我们认为,这有助于使核心脏病学成为评估人类心脏最准确和可重复的方式。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验