Derdilopoulou Foteini V, Zantner Catharina, Neumann Konrad, Kielbassa Andrej M
Department of Operative Dentistry and Periodontology, University School of Dental Medicine, Campus Benjamin Franklin, Charité-Universitätsmedizin Berlin, Germany.
Int J Prosthodont. 2007 Jul-Aug;20(4):414-6.
This study aimed to evaluate the performance of visual and spectrophotometric tooth shade analysis. Two operators independently selected the best match of 3758 anterior teeth of 106 patients at 3 different dates, using the Chromascop-Complete shade guide. Additionally, tooth color was analyzed 3 consecutive times using a reflectance spectrophotometer. Spectrophotometry showed high agreement values (89.6%); both examiners agreed in 49.7% of the measurements. Visual assessment resulted in significantly darker ratings than spectrophotometry (P < .0005). However, a positive association was observed for both procedures (P = .548). Spectrophotometric shade determination seems to be significantly more reproducible than the visual procedure.