Cholesterol esterase (ChEt) and cholesterol oxidase (ChOx) have been covalently immobilized on electrochemically prepared polyaniline (PANI) films. These PANI/ChEt/ChOx enzyme films have been characterized using UV-visible, Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). Electrochemical behavior of these films has been studied using cyclic voltammetry (CV) and amperometric techniques, respectively. The PANI/ChEt/ChOx enzyme films show broad oxidation peak from 0.2 to 0.5 V. These PANI/ChEt/ChOx biosensing electrodes have a response time of about 40s, linearity from 50 to 500 mg/dl of cholesterol oleate concentration. These PANI/ChEt/ChOx films are thermally stable up to 46 degrees C. This polyaniline based cholesterol biosensor has optimum pH in the range of 6.5-7.5, sensitivity as 7.5x10(-4) nA/mg dl and a lifetime of about 6 weeks.
胆固醇酯酶(ChEt)和胆固醇氧化酶(ChOx)已被共价固定在电化学制备的聚苯胺(PANI)薄膜上。这些聚苯胺/胆固醇酯酶/胆固醇氧化酶酶膜已通过紫外可见光谱、傅里叶变换红外(FTIR)光谱和扫描电子显微镜(SEM)进行了表征。分别使用循环伏安法(CV)和安培技术研究了这些膜的电化学行为。聚苯胺/胆固醇酯酶/胆固醇氧化酶酶膜在0.2至0.5 V范围内显示出宽氧化峰。这些聚苯胺/胆固醇酯酶/胆固醇氧化酶生物传感电极的响应时间约为40秒,油酸胆固醇浓度在50至500 mg/dl范围内呈线性。这些聚苯胺/胆固醇酯酶/胆固醇氧化酶膜在高达46摄氏度时热稳定。这种基于聚苯胺的胆固醇生物传感器的最佳pH值在6.5 - 7.5范围内,灵敏度为7.5×10^(-4) nA/mg dl,寿命约为6周。