Pohjola Randall M, Hackman Steven T, Browning William D
Veterans Administration Hospital, Augusta, GA 30904, USA.
Quintessence Int. 2007 Sep;38(8):671-6.
To determine if surface disinfectants cause a change in the shade perception of a standard Classic Vitapan shade guide.
Consistency in shade selection for dental restorations involves many factors, and one of the most important is the shade tabs used in the selection process. Ten shade tabs each of shades B2, D2, C1, and A3.5 were selected from the Classic Vitapan shade guide (Vident). All tabs were measured with the EasyShade shade device (Vident) at baseline. Three tabs of each shade were set aside as controls. The other 7 tabs of each shade were treated with the surface disinfectant Cavicide (Metrex Research) for 480 cycles to simulate a year's usage. After each 480 cycles, all the tabs were again measured with the EasyShade. This process was repeated to simulate 2 and 3 years of use.
The data were analyzed to calculate the delta E 2000 for any change. A statistically significant increase was observed in the value (L*) and chroma (C*) after 2 and 3 years of simulated treatments. These changes were not perceptible to the clinician.
The authors suggest that 1 standard shade guide be set aside to compare against those in clinical use to determine when they should be replaced.
确定表面消毒剂是否会导致标准的经典维他潘比色板的颜色感知发生变化。
牙科修复体颜色选择的一致性涉及许多因素,其中最重要的因素之一是选择过程中使用的比色片。从经典维他潘比色板(Vident)中选取了每种色号B2、D2、C1和A3.5的10个比色片。所有比色片在基线时均使用易比色比色仪(Vident)进行测量。每种色号的3个比色片留作对照。每种色号的其他7个比色片用表面消毒剂卡维地(Metrex Research)处理480个循环以模拟一年的使用情况。每480个循环后,所有比色片再次用易比色比色仪进行测量。重复此过程以模拟2年和3年的使用情况。
对数据进行分析以计算任何变化的ΔE2000。在模拟处理2年和3年后,观察到明度值(L*)和彩度值(C*)有统计学上的显著增加。这些变化临床医生无法察觉。
作者建议留出1个标准比色板,与临床使用的比色板进行比较,以确定何时应更换比色板。