Abstract

BACKGROUND

The aims of the present study were to compare the diagnostic and clinical value of seven commercially available assays for second-generation anti-cyclic citrullinated peptide (CCP2) antibodies, anti-keratin antibodies (AKA) and rheumatoid factor (RF) determination in patients with rheumatoid arthritis (RA), and to check the potential advantages of a third-generation anti-CCP (CCP3) antibodies assay.

METHODS

Serum samples from 120 RA patients and from 170 controls were used to determine the sensitivity, the specificity, the positive (PPV) and negative predictive values (NPV) of CCP2 and CCP3 antibodies, AKA and RF assays. The respective performances of these tests were compared using a receiver-operating characteristics (ROC) curves methodology.

RESULTS

We found no significant differences in sensitivity and specificity between the tested anti-CCP assays. The CCP3 antibodies assay we evaluated was not significantly more sensitive than those of the second generation. Compared with RF technique, all anti-CCP assays showed better specificity, but lower sensitivity. In contrast, while of equivalent specificity, they proved to be more sensitive than AKA in the discrimination of RA from other rheumatic diseases.

CONCLUSIONS

Anti-CCP antibodies determination proved to be a powerful diagnostic tool, especially in RA patients with negative AKA or RF. The investigated CCP3 antibodies assay had no better diagnostic performances than the second-generation assays.

摘要

背景

本研究旨在比较七种市售检测方法在类风湿关节炎(RA)患者中检测第二代抗环瓜氨酸肽(CCP2)抗体、抗角蛋白抗体(AKA)和类风湿因子(RF)的诊断和临床价值,并检验第三代抗CCP(CCP3)抗体检测方法的潜在优势。

方法

采用120例RA患者和170例对照的血清样本,测定CCP2和CCP3抗体、AKA和RF检测方法的敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)。使用受试者工作特征(ROC)曲线方法比较这些检测方法的各自性能。

结果

我们发现所检测的抗CCP检测方法在敏感性和特异性方面无显著差异。我们评估的CCP3抗体检测方法并不比第二代检测方法显著更敏感。与RF技术相比,所有抗CCP检测方法均显示出更好的特异性,但敏感性较低。相比之下,虽然特异性相当,但在区分RA与其他风湿性疾病方面,它们比AKA更敏感。

结论

抗CCP抗体检测被证明是一种强大的诊断工具,尤其是在AKA或RF阴性的RA患者中。所研究的CCP3抗体检测方法的诊断性能并不优于第二代检测方法。